Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
769
matching recommendationsNAICS | 325412 | Pharmaceutical Preparation Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0259 # 04 Y:2007 | 04 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,735 | $37,000 | Implemented |
LE0259 # 05 Y:2007 | 05 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,811 | $200 | Implemented |
LE0259 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,501 | $50 | Not Implemented |
LE0259 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,938 | $4,386 | Not Implemented |
MS0318 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,453 | $34,528 | Implemented |
MS0318 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,884 | $20,897 | Implemented |
MS0318 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,013 | $401 | Implemented |
MS0318 # 04 Y:2007 | 04 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $2,805 | $156 | Implemented |
MS0318 # 05 Y:2007 | 05 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $747 | $378 | Not Implemented |
MS0318 # 06 Y:2007 | 06 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $587 | $0 | Implemented |
MS0318 # 07 Y:2007 | 07 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $205 | $434 | Not Implemented |
LL0271 # 01 Y:2007 | 01 | 2007 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $78,849 | $24,500 | Not Implemented |
LL0271 # 02 Y:2007 | 02 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $17,275 | $1,587 | Not Implemented |
LL0271 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,710 | $3,760 | Implemented |
LL0271 # 04 Y:2007 | 04 | 2007 | INSTALL OCCUPANCY SENSORS | $7,569 | $3,000 | Not Implemented |
LL0271 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,159 | $5,905 | Implemented |
LL0271 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,133 | $15 | Not Implemented |
LL0271 # 07 Y:2007 | 07 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,580 | $2,366 | Implemented |
LL0271 # 08 Y:2007 | 08 | 2007 | INSULATE BARE EQUIPMENT | $1,886 | $1,500 | Implemented |
LL0271 # 09 Y:2007 | 09 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $365 | $638 | Implemented |
LL0271 # 10 Y:2007 | 10 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $252 | $454 | Implemented |
SF0340 # 01 Y:2007 | 01 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,354 | $0 | Implemented |
SF0340 # 02 Y:2007 | 02 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $12,059 | $320 | Implemented |
SF0340 # 03 Y:2007 | 03 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $6,510 | $0 | Implemented |
SF0340 # 04 Y:2007 | 04 | 2007 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $155,963 | $36,556 | Implemented |