Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
399
matching recommendationsNAICS | 325510 | Paint and Coating Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0405 # 04 Y:2010 | 04 | 2010 | TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS | $31,421 | $0 | Not Implemented |
DL0049 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,599 | $50 | Not Implemented |
DL0049 # 02 Y:2010 | 02 | 2010 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $35,889 | $1,500 | Implemented |
DL0049 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $43,192 | $2,000 | Implemented |
DL0049 # 04 Y:2010 | 04 | 2010 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $7,180 | $1,000 | Implemented |
DL0049 # 05 Y:2010 | 05 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $17,413 | $2,500 | Implemented |
DL0049 # 06 Y:2010 | 06 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,857 | $2,180 | Not Implemented |
DL0049 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $51,500 | $30,000 | Implemented |
DL0049 # 08 Y:2010 | 08 | 2010 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $190 | $435 | Not Implemented |
LE0294 # 01 Y:2010 | 01 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $62,047 | $3,000 | Not Implemented |
LE0294 # 02 Y:2010 | 02 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $16,939 | $3,600 | Not Implemented |
LE0294 # 03 Y:2010 | 03 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,696 | $12,000 | Not Implemented |
LE0294 # 04 Y:2010 | 04 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,495 | $3,000 | Implemented |
LE0294 # 05 Y:2010 | 05 | 2010 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $3,844 | $6,000 | Not Implemented |
LE0294 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,248 | $1,824 | Implemented |
LE0294 # 07 Y:2010 | 07 | 2010 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $2,376 | $2,550 | Not Implemented |
LE0294 # 08 Y:2010 | 08 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,483 | $800 | Not Implemented |
LE0294 # 09 Y:2010 | 09 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $575 | $40 | Not Implemented |
OK0786 # 01 Y:2010 | 01 | 2010 | OPERATE BOILERS ON HIGH FIRE SETTING | $2,348 | $24,000 | Not Implemented |
OK0786 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $106 | $604 | Not Implemented |
OK0786 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $453 | $3,410 | Not Implemented |
OK0786 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $854 | $0 | Implemented |
OK0786 # 05 Y:2010 | 05 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $1,491 | $465 | Implemented |
OK0786 # 06 Y:2010 | 06 | 2010 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $903 | $0 | Implemented |
IC0164 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,002 | $21,920 | Implemented |