Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
564
matching recommendationsNAICS | 3256 | Soap, Cleaning Compound, and Toilet Preparation Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0347 # 09 Y:2012 | 09 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $988 | $4,050 | Not Implemented |
LE0322 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,515 | $1,000 | Implemented |
LE0322 # 02 Y:2011 | 02 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,000 | $8,500 | Implemented |
LE0322 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $781 | $8,625 | Not Implemented |
LE0322 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $188 | $175 | Not Implemented |
IC0185 # 01 Y:2011 | 01 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $1,075 | $200 | Not Implemented |
IC0185 # 02 Y:2011 | 02 | 2011 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $66,621 | $315,096 | n/a |
IC0185 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $604 | $1,719 | n/a |
IC0185 # 04 Y:2011 | 04 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $283 | $1 | n/a |
IC0185 # 05 Y:2011 | 05 | 2011 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,057 | $115 | n/a |
IC0185 # 06 Y:2011 | 06 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $205 | $334 | n/a |
IC0185 # 07 Y:2011 | 07 | 2011 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $260,354 | $102,100 | n/a |
UD0832 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,751 | $40,000 | Implemented |
UD0832 # 02 Y:2011 | 02 | 2011 | DISCONNECT BALLASTS | $2,570 | $250 | Implemented |
UD0832 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $1,977 | $1,063 | Implemented |
UD0832 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $56,419 | $39,141 | Implemented |
UD0832 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,473 | $16,265 | Not Implemented |
UD0832 # 06 Y:2011 | 06 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $4,243 | $4,728 | Implemented |
UD0832 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $986 | $500 | Implemented |
UD0832 # 08 Y:2011 | 08 | 2011 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $5,424 | $500 | Implemented |
UD0832 # 09 Y:2011 | 09 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $25,624 | $5,000 | Not Implemented |
UD0832 # 10 Y:2011 | 10 | 2011 | REPAIR OR REPLACE STEAM TRAPS | $14,246 | $2,000 | Not Implemented |
UD0832 # 11 Y:2011 | 11 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,335 | $2,620 | Not Implemented |
UD0832 # 12 Y:2011 | 12 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,554 | $5,000 | Not Implemented |
LL0296 # 01 Y:2008 | 01 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $463,124 | $9,955 | Not Implemented |