Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
923
matching recommendationsNAICS | 3259 | Other Chemical Product and Preparation Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0088 # 02 Y:2004 | 02 | 2004 | USE OPTIMUM THICKNESS INSULATION | $86,400 | $1,610 | Not Implemented |
TA0088 # 03 Y:2004 | 03 | 2004 | INSULATE BARE EQUIPMENT | $66,520 | $1,010 | Implemented |
TA0088 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $20,580 | $15,340 | Not Implemented |
TA0088 # 05 Y:2004 | 05 | 2004 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $15,810 | $2,000 | Implemented |
TA0088 # 06 Y:2004 | 06 | 2004 | REDUCE OR ELIMINATE WASTE | $18,000 | $1,000 | Implemented |
TA0088 # 07 Y:2004 | 07 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,995 | $1,000 | Implemented |
TA0088 # 08 Y:2004 | 08 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,000 | $0 | Not Implemented |
LM0083 # 01 Y:2004 | 01 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $28,411 | $5,040 | Not Implemented |
LM0083 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $836 | $0 | Implemented |
LM0083 # 03 Y:2004 | 03 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $110 | $150 | Implemented |
LM0083 # 04 Y:2004 | 04 | 2004 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $21,186 | $3,081 | Not Implemented |
LM0083 # 05 Y:2004 | 05 | 2004 | UTILIZE OUTSIDE CONTRACTING | $4,988 | $500 | Not Implemented |
LM0083 # 06 Y:2004 | 06 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,561 | $8,800 | Not Implemented |
UM0261 # 01 Y:2004 | 01 | 2004 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $96,676 | $11,096 | Not Implemented |
UM0261 # 02 Y:2004 | 02 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,377 | $47,700 | Not Implemented |
UM0261 # 03 Y:2004 | 03 | 2004 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $7,493 | $2,000 | Implemented |
UM0261 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $6,503 | $500 | Implemented |
UM0261 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,770 | $1,711 | Implemented |
UM0261 # 06 Y:2004 | 06 | 2004 | COVER OPEN TANKS | $625 | $300 | Implemented |
BD0246 # 01 Y:2003 | 01 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $24,786 | $15,000 | Implemented |
BD0246 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,982 | $31,690 | Implemented |
BD0246 # 03 Y:2003 | 03 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $7,990 | $15,285 | Not Implemented |
BD0246 # 04 Y:2003 | 04 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,890 | $200 | Implemented |
BD0246 # 05 Y:2003 | 05 | 2003 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $5,102 | $3,000 | Not Implemented |
BD0246 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,063 | $1,000 | Implemented |