Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
184
matching recommendationsNAICS | 325991 | Custom Compounding of Purchased Resins |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0537 # 06 Y:2017 | 06 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $6,093 | $6,000 | Not Implemented |
WV0537 # 05 Y:2017 | 05 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,210 | $0 | Implemented |
WV0537 # 04 Y:2017 | 04 | 2017 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $7,934 | $1,200 | Implemented |
WV0537 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,952 | $7,891 | Implemented |
WV0537 # 02 Y:2017 | 02 | 2017 | USE EVAPORATION TO CONCENTRATE MATERIAL | $18,040 | $80,000 | Not Implemented |
WV0537 # 01 Y:2017 | 01 | 2017 | USE SCREENING, MAGNETIC SEPARATION TO REMOVE CONTAMINANTS | $86,765 | $200,500 | Not Implemented |
TT0162 # 07 Y:2015 | 07 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,792 | $1,075 | Not Implemented |
TT0162 # 06 Y:2015 | 06 | 2015 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,012 | $2,000 | Not Implemented |
TT0162 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,958 | $3,000 | Implemented |
TT0162 # 04 Y:2015 | 04 | 2015 | INSTALL SPECTRAL REFLECTORS / DELAMP | $5,229 | $706 | Not Implemented |
TT0162 # 03 Y:2015 | 03 | 2015 | INSTALL OCCUPANCY SENSORS | $7,531 | $16,988 | Not Implemented |
TT0162 # 02 Y:2015 | 02 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,231 | $11,000 | Not Implemented |
TT0162 # 01 Y:2015 | 01 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,039 | $10,000 | Implemented |
OK0917 # 06 Y:2015 | 06 | 2015 | USE OPTIMUM TEMPERATURE | $8,870 | $180 | Implemented |
OK0917 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $689 | $577 | Implemented |
OK0917 # 04 Y:2015 | 04 | 2015 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $4,875 | $2,000 | Implemented |
OK0917 # 03 Y:2015 | 03 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $537 | $55 | Implemented |
OK0917 # 02 Y:2015 | 02 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,154 | $72 | Implemented |
OK0917 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,019 | $6,287 | Not Implemented |
MA0681 # 05 Y:2011 | 05 | 2011 | INSULATE BARE EQUIPMENT | $152 | $80 | Not Implemented |
MA0681 # 04 Y:2011 | 04 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $768 | $300 | Not Implemented |
MA0681 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $1,163 | $1,265 | Implemented |
MA0681 # 02 Y:2011 | 02 | 2011 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $1,294 | $1,220 | Not Implemented |
MA0681 # 01 Y:2011 | 01 | 2011 | REDUCE VENTILATION AIR | $6,162 | $9,261 | Implemented |
WV0417 # 08 Y:2010 | 08 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,656 | $1,188 | Implemented |