IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

184

matching recommendations
Reset
NAICS 325991 Custom Compounding of Purchased Resins
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0547 # 04 Y:2008 04 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $14,600 $700 Not Implemented
AM0547 # 05 Y:2008 05 2008 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $7,000 $0 Not Implemented
AM0547 # 06 Y:2008 06 2008 USE SYNTHETIC LUBRICANT $4,300 $0 Not Implemented
AM0547 # 07 Y:2008 07 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,150 $500 Not Implemented
AM0547 # 08 Y:2008 08 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $170 $390 Not Implemented
UM0324 # 01 Y:2007 01 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,396 $2,140 Not Implemented
UM0324 # 02 Y:2007 02 2007 INSULATE BARE EQUIPMENT $5,954 $543 Not Implemented
UM0324 # 03 Y:2007 03 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,631 $4,000 Not Implemented
UM0324 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,978 $0 Implemented
UM0324 # 05 Y:2007 05 2007 OPTIMIZE PLANT POWER FACTOR $7,222 $6,917 Implemented
UD0753 # 01 Y:2007 01 2007 $98,450 $3,040 Implemented
UD0753 # 02 Y:2007 02 2007 REDUCE VENTILATION AIR $67,600 $19,800 Implemented
UD0753 # 03 Y:2007 03 2007 REDUCE VENTILATION AIR $36,200 $10,000 Not Implemented
UD0753 # 04 Y:2007 04 2007 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $35,807 $30,000 Not Implemented
UD0753 # 05 Y:2007 05 2007 INSULATE BARE EQUIPMENT $11,994 $7,875 Implemented
UD0753 # 06 Y:2007 06 2007 USE RADIANT HEATER FOR SPOT HEATING $10,800 $15,600 Implemented
UD0753 # 07 Y:2007 07 2007 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $8,390 $15,000 Implemented
UD0753 # 08 Y:2007 08 2007 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $5,105 $16,500 Not Implemented
UD0753 # 09 Y:2007 09 2007 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,816 $0 Implemented
UD0753 # 10 Y:2007 10 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,007 $0 Not Implemented
UD0753 # 11 Y:2007 11 2007 USE OPTIMUM TEMPERATURE $998 $0 Implemented
UD0753 # 12 Y:2007 12 2007 OPTIMIZE PLANT POWER FACTOR $864 $9,000 Not Implemented
UD0753 # 13 Y:2007 13 2007 UPGRADE CONTROLS ON COMPRESSORS $299 $3,800 Not Implemented
LE0217 # 01 Y:2005 01 2005 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $33,752 $27,000 Not Implemented
LE0217 # 02 Y:2005 02 2005 KEEP EQUIPMENT CLEAN $28,000 $840 Implemented