Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
169
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0650 # 05 Y:2011 | 05 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $740 | $1,470 | Implemented |
CO0650 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,420 | $9,240 | Implemented |
CO0650 # 01 Y:2011 | 01 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,700 | $1,000 | Implemented |
TT0082 # 05 Y:2011 | 05 | 2011 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,673 | $15 | Implemented |
TT0082 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,923 | $18,044 | Implemented |
TT0082 # 07 Y:2011 | 07 | 2011 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $952 | $2,625 | Implemented |
TT0082 # 04 Y:2011 | 04 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,256 | $1,480 | Implemented |
DL0074 # 03 Y:2011 | 03 | 2011 | KEEP EQUIPMENT CLEAN | $9,770 | $2,000 | Implemented |
DL0074 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,320 | $1,900 | Implemented |
DL0074 # 10 Y:2011 | 10 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $510 | $1,300 | Implemented |
DL0074 # 02 Y:2011 | 02 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $12,050 | $4,500 | Implemented |
DL0074 # 01 Y:2011 | 01 | 2011 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $6,390 | $2,000 | Implemented |
UD0843 # 09 Y:2011 | 09 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,145 | $650 | Implemented |
UD0843 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,289 | $4,698 | Implemented |
UD0843 # 02 Y:2011 | 02 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,770 | $0 | Implemented |
UD0843 # 06 Y:2011 | 06 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,854 | $0 | Implemented |
UD0843 # 08 Y:2011 | 08 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $509 | $0 | Implemented |
WV0435 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,437 | $4,415 | Implemented |
WV0435 # 11 Y:2011 | 11 | 2011 | USE SYNTHETIC LUBRICANT | $608 | $516 | Implemented |
WV0435 # 06 Y:2011 | 06 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $1,546 | $668 | Implemented |
WV0435 # 02 Y:2011 | 02 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,088 | $2,144 | Implemented |
WV0435 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,758 | $272 | Implemented |
WV0435 # 13 Y:2011 | 13 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $190 | $16 | Implemented |
WV0435 # 12 Y:2011 | 12 | 2011 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $330 | $66 | Implemented |
WV0435 # 09 Y:2011 | 09 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,230 | $1,000 | Implemented |