Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,572
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0354 # 04 Y:2009 | 04 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $12,144 | $4,200 | Implemented |
UM0354 # 06 Y:2009 | 06 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,114 | $500 | Implemented |
UM0354 # 07 Y:2009 | 07 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $983 | $200 | Implemented |
SU0285 # 01 Y:2009 | 01 | 2009 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $95,326 | $0 | Implemented |
SU0285 # 02 Y:2009 | 02 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,684 | $0 | Implemented |
SU0285 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,090 | $460 | Implemented |
SU0285 # 07 Y:2009 | 07 | 2009 | INSTALL OCCUPANCY SENSORS | $4,200 | $2,508 | Implemented |
SU0285 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,299 | $18,800 | Implemented |
MZ0036 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,757 | $26,855 | Implemented |
MZ0036 # 04 Y:2009 | 04 | 2009 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $4,395 | $8,757 | Implemented |
MZ0036 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $62,000 | $850 | Implemented |
IA0441 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,444 | $702 | Implemented |
IA0441 # 07 Y:2009 | 07 | 2009 | INSTALL OCCUPANCY SENSORS | $853 | $479 | Implemented |
IA0441 # 08 Y:2009 | 08 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,129 | $760 | Implemented |
IA0441 # 10 Y:2009 | 10 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $25,097 | $27,000 | Implemented |
IA0441 # 11 Y:2009 | 11 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,289 | $16,600 | Implemented |
UA0039 # 01 Y:2009 | 01 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,022 | $0 | Implemented |
UA0039 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,998 | $1,500 | Implemented |
BD0362 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,931 | $36,000 | Implemented |
BD0362 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $398 | $325 | Implemented |
BD0362 # 03 Y:2009 | 03 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $701 | $100 | Implemented |
BD0362 # 04 Y:2009 | 04 | 2009 | USE SYNTHETIC LUBRICANT | $1,202 | $300 | Implemented |
BD0362 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,945 | $2,900 | Implemented |
BD0362 # 06 Y:2009 | 06 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,913 | $3,300 | Implemented |
BD0362 # 10 Y:2009 | 10 | 2009 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,248 | $520 | Implemented |