Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
354
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0084 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,987 | $500 | Not Implemented |
MZ0084 # 04 Y:2012 | 04 | 2012 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,897 | $2,400 | Not Implemented |
MZ0084 # 05 Y:2012 | 05 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $12,831 | $37,520 | Not Implemented |
MZ0084 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $7,736 | $11,730 | Implemented |
MZ0084 # 07 Y:2012 | 07 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,142 | $1,000 | Not Implemented |
MZ0084 # 08 Y:2012 | 08 | 2012 | ELIMINATE/REDUCE AN OPERATION | $6,939 | $0 | Implemented |
MZ0084 # 09 Y:2012 | 09 | 2012 | INSULATE BARE EQUIPMENT | $1,483 | $2,500 | Implemented |
MZ0084 # 10 Y:2012 | 10 | 2012 | OPERATE BOILERS ON HIGH FIRE SETTING | $10,918 | $1,770 | Implemented |
MZ0055 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,916 | $1,100 | Implemented |
MZ0055 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $770 | $700 | Not Implemented |
MZ0055 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,900 | $1,160 | Implemented |
MZ0055 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,282 | $16,460 | Implemented |
MZ0055 # 05 Y:2010 | 05 | 2010 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $8,888 | $0 | Not Implemented |
MZ0055 # 06 Y:2010 | 06 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $0 | $0 | Implemented |
MZ0055 # 07 Y:2010 | 07 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $0 | $0 | Implemented |
MZ0045 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,876 | $46,050 | Implemented |
MZ0045 # 02 Y:2009 | 02 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,746 | $4,200 | Not Implemented |
MZ0045 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,734 | $950 | Implemented |
MZ0045 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,645 | $0 | Implemented |
MZ0045 # 05 Y:2009 | 05 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $23,660 | $0 | Implemented |
MZ0043 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,595 | $20,400 | Implemented |
MZ0043 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,634 | $860 | Implemented |
MZ0043 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $2,319 | $480 | Implemented |
MZ0043 # 04 Y:2009 | 04 | 2009 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $627 | $1,800 | Implemented |
MZ0043 # 05 Y:2009 | 05 | 2009 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $7,387 | $3,600 | Implemented |