Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
393
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0814 # 12 Y:2010 | 12 | 2010 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $3,484 | $0 | Implemented |
UD0798 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $177,970 | $480,000 | Not Implemented |
UD0798 # 02 Y:2009 | 02 | 2009 | INSULATE BARE EQUIPMENT | $56,464 | $62,640 | Not Implemented |
UD0798 # 03 Y:2009 | 03 | 2009 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $28,050 | $0 | Not Implemented |
UD0798 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,344 | $62,000 | Implemented |
UD0798 # 05 Y:2009 | 05 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $22,669 | $32,084 | Not Implemented |
UD0798 # 06 Y:2009 | 06 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $21,417 | $0 | Implemented |
UD0798 # 07 Y:2009 | 07 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,830 | $25,242 | Not Implemented |
UD0798 # 08 Y:2009 | 08 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $7,626 | $0 | Implemented |
UD0798 # 09 Y:2009 | 09 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,462 | $0 | Implemented |
UD0798 # 10 Y:2009 | 10 | 2009 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $1,678 | $0 | Implemented |
UD0798 # 11 Y:2009 | 11 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $341 | $0 | Implemented |
UD0751 # 04 Y:2006 | 04 | 2006 | OPTIMIZE PLANT POWER FACTOR | $21,149 | $61,500 | Not Implemented |
UD0751 # 03 Y:2006 | 03 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $32,112 | $0 | Not Implemented |
UD0751 # 02 Y:2006 | 02 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $63,687 | $0 | Implemented |
UD0751 # 01 Y:2006 | 01 | 2006 | REDUCE EXCESS STEAM BLEEDING | $90,000 | $18,000 | Not Implemented |
UD0751 # 05 Y:2006 | 05 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $13,248 | $10,000 | Not Implemented |
UD0751 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,066 | $28,800 | Not Implemented |
UD0751 # 07 Y:2006 | 07 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,000 | $0 | Not Implemented |
UD0751 # 08 Y:2006 | 08 | 2006 | HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS | $8,395 | $2,000 | Not Implemented |
UD0751 # 09 Y:2006 | 09 | 2006 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $7,062 | $12,000 | Not Implemented |
UD0751 # 10 Y:2006 | 10 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,759 | $5,000 | Implemented |
UD0723 # 14 Y:2005 | 14 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $840 | $0 | Not Implemented |
UD0723 # 02 Y:2005 | 02 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,430 | $0 | Implemented |
UD0723 # 15 Y:2005 | 15 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $522 | $0 | Implemented |