Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
410
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0853 # 07 Y:2012 | 07 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,012 | $1,000 | Not Implemented |
UD0853 # 08 Y:2012 | 08 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,506 | $1,000 | Not Implemented |
UD0853 # 09 Y:2012 | 09 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $974 | $2,000 | Not Implemented |
UD0853 # 10 Y:2012 | 10 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $402 | $1,300 | Not Implemented |
UD0853 # 11 Y:2012 | 11 | 2012 | COVER OPEN TANKS | $4,120 | $200 | Not Implemented |
UD0853 # 12 Y:2012 | 12 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,076 | $9,000 | Not Implemented |
UD0814 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36,324 | $60,476 | Implemented |
UD0814 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,387 | $28,012 | Implemented |
UD0814 # 03 Y:2010 | 03 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,684 | $21,115 | Not Implemented |
UD0814 # 04 Y:2010 | 04 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $899 | $1,724 | Implemented |
UD0814 # 05 Y:2010 | 05 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $386 | $0 | Implemented |
UD0814 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,642 | $1,000 | Implemented |
UD0814 # 07 Y:2010 | 07 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $137 | $540 | Not Implemented |
UD0814 # 08 Y:2010 | 08 | 2010 | INSULATE BARE EQUIPMENT | $18,417 | $9,030 | Not Implemented |
UD0814 # 09 Y:2010 | 09 | 2010 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $8,568 | $3,000 | Implemented |
UD0814 # 10 Y:2010 | 10 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,017 | $400 | Implemented |
UD0814 # 11 Y:2010 | 11 | 2010 | INSULATE BARE EQUIPMENT | $1,111 | $807 | Not Implemented |
UD0814 # 12 Y:2010 | 12 | 2010 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $3,484 | $0 | Implemented |
UD0798 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $177,970 | $480,000 | Not Implemented |
UD0798 # 02 Y:2009 | 02 | 2009 | INSULATE BARE EQUIPMENT | $56,464 | $62,640 | Not Implemented |
UD0798 # 03 Y:2009 | 03 | 2009 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $28,050 | $0 | Not Implemented |
UD0798 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,344 | $62,000 | Implemented |
UD0798 # 05 Y:2009 | 05 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $22,669 | $32,084 | Not Implemented |
UD0798 # 06 Y:2009 | 06 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $21,417 | $0 | Implemented |
UD0798 # 07 Y:2009 | 07 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,830 | $25,242 | Not Implemented |