Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
627
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0400 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $9,933 | $14,699 | Not Implemented |
SF0400 # 07 Y:2011 | 07 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,404 | $22,616 | Not Implemented |
SF0400 # 08 Y:2011 | 08 | 2011 | OPTIMIZE PLANT POWER FACTOR | $5,731 | $15,119 | Not Implemented |
SF0400 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,700 | $41,732 | Not Implemented |
SF0400 # 10 Y:2011 | 10 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $23,990 | $67,329 | Not Implemented |
SF0400 # 11 Y:2011 | 11 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $31,158 | $170,718 | Not Implemented |
SF0400 # 12 Y:2011 | 12 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $171,695 | $1,807,809 | Not Implemented |
SD0435 # 01 Y:2011 | 01 | 2011 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $704 | $0 | Implemented |
SD0435 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,875 | $700 | Implemented |
SD0435 # 03 Y:2011 | 03 | 2011 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $14,990 | $3,784 | Not Implemented |
SD0435 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,988 | $4,310 | Implemented |
SD0435 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,282 | $1,000 | Implemented |
SD0435 # 06 Y:2011 | 06 | 2011 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $866 | $840 | Implemented |
SF0395 # 01 Y:2011 | 01 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $6,724 | $0 | Implemented |
SF0395 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,312 | $0 | Implemented |
SF0395 # 03 Y:2011 | 03 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,795 | $4,576 | Not Implemented |
SF0395 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,313 | $7,243 | Implemented |
SF0395 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,833 | $5,753 | Implemented |
SF0395 # 06 Y:2011 | 06 | 2011 | USE COMPRESSOR AIR FILTERS | $1,038 | $1,467 | Implemented |
SF0395 # 07 Y:2011 | 07 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,112 | $6,182 | Implemented |
SF0395 # 08 Y:2011 | 08 | 2011 | INSTALL OCCUPANCY SENSORS | $3,218 | $6,195 | Not Implemented |
SF0395 # 09 Y:2011 | 09 | 2011 | INSULATE BARE EQUIPMENT | $8,140 | $22,037 | Implemented |
SF0395 # 10 Y:2011 | 10 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $4,772 | $18,000 | Implemented |
SF0395 # 11 Y:2011 | 11 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,959 | $41,361 | Not Implemented |
SF0395 # 12 Y:2011 | 12 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $96,436 | $3,735,000 | Not Implemented |