Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,415

matching recommendations
Reset
NAICS 326 Plastics and Rubber Products Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0885 # 05 Y:2013 05 2013 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $120,105 $0 Not Implemented
UD0885 # 06 Y:2013 06 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,143 $0 Not Implemented
UD0885 # 07 Y:2013 07 2013 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $101,273 $58,500 Not Implemented
UD0885 # 08 Y:2013 08 2013 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,705 $3,600 Not Implemented
UD0885 # 09 Y:2013 09 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,587 $1,100 Not Implemented
UD0885 # 10 Y:2013 10 2013 INSULATE BARE EQUIPMENT $6,356 $946 Not Implemented
UD0885 # 11 Y:2013 11 2013 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,958 $0 Implemented
UD0885 # 12 Y:2013 12 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $988 $3,250 Not Implemented
UD0885 # 13 Y:2013 13 2013 USE SOLAR HEAT TO MAKE ELECTRICTY $33,106 $294,000 Not Implemented
UM0429 # 01 Y:2013 01 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $34,689 $59,040 Implemented
UM0429 # 02 Y:2013 02 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,926 $1,000 Not Implemented
UM0429 # 03 Y:2013 03 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $9,525 $1,000 Implemented
UM0429 # 04 Y:2013 04 2013 RECOVER WASTE HEAT FROM EQUIPMENT $23,321 $5,000 Implemented
UM0429 # 05 Y:2013 05 2013 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,185 $4,420 Not Implemented
DL0108 # 01 Y:2013 01 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $39,709 $0 Implemented
DL0108 # 02 Y:2013 02 2013 ADJUST VENTS TO MINIMIZE ENERGY USE $3,279 $0 Not Implemented
DL0108 # 03 Y:2013 03 2013 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $13,367 $0 Implemented
DL0108 # 04 Y:2013 04 2013 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,687 $270 Implemented
DL0108 # 05 Y:2013 05 2013 INSTALL TIMERS AND/OR THERMOSTATS $500 $200 Implemented
DL0108 # 06 Y:2013 06 2013 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $2,400 $400 Not Implemented
DL0108 # 07 Y:2013 07 2013 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $543 $0 Implemented
DL0108 # 08 Y:2013 08 2013 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $186,000 $500,000 Not Implemented
SD0475 # 01 Y:2013 01 2013 REDUCE SCRAP PRODUCTION $478,006 $153,240 Not Implemented
SD0475 # 02 Y:2013 02 2013 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $74,589 $105,000 Not Implemented
SD0475 # 03 Y:2013 03 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $72,583 $20,000 Not Implemented