Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,415
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0039 # 04 Y:2009 | 04 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $4,828 | $170 | Not Implemented |
UA0039 # 05 Y:2009 | 05 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $68,100 | $11,400 | Not Implemented |
UA0039 # 06 Y:2009 | 06 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $8,365 | $1,219 | Not Implemented |
UA0039 # 07 Y:2009 | 07 | 2009 | REPAIR AND ELIMINATE STEAM LEAKS | $46,967 | $1,450 | Not Implemented |
UA0039 # 08 Y:2009 | 08 | 2009 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $22,160 | $33,000 | Not Implemented |
BD0362 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,931 | $36,000 | Implemented |
BD0362 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $398 | $325 | Implemented |
BD0362 # 03 Y:2009 | 03 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $701 | $100 | Implemented |
BD0362 # 04 Y:2009 | 04 | 2009 | USE SYNTHETIC LUBRICANT | $1,202 | $300 | Implemented |
BD0362 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,945 | $2,900 | Implemented |
BD0362 # 06 Y:2009 | 06 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,913 | $3,300 | Implemented |
BD0362 # 07 Y:2009 | 07 | 2009 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $7,156 | $60,000 | Not Implemented |
BD0362 # 08 Y:2009 | 08 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $200 | $0 | Not Implemented |
BD0362 # 09 Y:2009 | 09 | 2009 | USE POWER DURING OFF-PEAK PERIODS | $15,684 | $2,000 | Not Implemented |
BD0362 # 10 Y:2009 | 10 | 2009 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,248 | $520 | Implemented |
UW0029 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $13,416 | $120,000 | Implemented |
UW0029 # 02 Y:2009 | 02 | 2009 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $10,263 | $17,000 | Implemented |
UW0029 # 03 Y:2009 | 03 | 2009 | INSULATE BARE EQUIPMENT | $3,269 | $3,800 | Implemented |
UW0029 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,713 | $9,934 | Implemented |
LE0287 # 01 Y:2009 | 01 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $184,606 | $250,000 | Not Implemented |
LE0287 # 02 Y:2009 | 02 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $220,823 | $50,000 | Not Implemented |
LE0287 # 03 Y:2009 | 03 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $79,515 | $8,000 | Not Implemented |
LE0287 # 04 Y:2009 | 04 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $36,003 | $650 | Not Implemented |
LE0287 # 05 Y:2009 | 05 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $19,644 | $17,000 | Not Implemented |
LE0287 # 06 Y:2009 | 06 | 2009 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $13,621 | $7,167 | Not Implemented |