Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,680
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0349 # 01 Y:2008 | 01 | 2008 | INSTALL OCCUPANCY SENSORS | $8,788 | $1,125 | Implemented |
BD0349 # 02 Y:2008 | 02 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $38,551 | $96,150 | Not Implemented |
BD0349 # 03 Y:2008 | 03 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,618 | $0 | Not Implemented |
BD0349 # 04 Y:2008 | 04 | 2008 | REPLACE BOILER | $205,005 | $110,000 | Not Implemented |
BD0349 # 05 Y:2008 | 05 | 2008 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $87,545 | $10,000 | Not Implemented |
BD0349 # 06 Y:2008 | 06 | 2008 | INSTALL TURBULATORS | $131,143 | $8,000 | Not Implemented |
BD0349 # 07 Y:2008 | 07 | 2008 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $128,022 | $46,000 | Not Implemented |
BD0349 # 08 Y:2008 | 08 | 2008 | MINIMIZE WATER USAGE | $991 | $2,300 | Not Implemented |
MZ0021 # 01 Y:2008 | 01 | 2008 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $20,665 | $20,000 | Implemented |
MZ0021 # 02 Y:2008 | 02 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,575 | $900 | Implemented |
MZ0021 # 03 Y:2008 | 03 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,015 | $5,000 | Implemented |
MZ0021 # 04 Y:2008 | 04 | 2008 | INSTALL SPECTRAL REFLECTORS / DELAMP | $565 | $40 | Implemented |
MZ0021 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,112 | $21,425 | Implemented |
MZ0021 # 06 Y:2008 | 06 | 2008 | INSTALL OCCUPANCY SENSORS | $855 | $740 | Not Implemented |
MZ0021 # 07 Y:2008 | 07 | 2008 | INSTALL OCCUPANCY SENSORS | $40 | $190 | Not Implemented |
OK0764 # 01 Y:2008 | 01 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,109 | $5,086 | Not Implemented |
OK0764 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,596 | $14,878 | Not Implemented |
OK0764 # 03 Y:2008 | 03 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $477 | $1,165 | Not Implemented |
OK0764 # 04 Y:2008 | 04 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $22,038 | $14,300 | Not Implemented |
OK0764 # 05 Y:2008 | 05 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $7,000 | $0 | Not Implemented |
OK0764 # 06 Y:2008 | 06 | 2008 | CLOSE OFF UNNEEDED STEAM LINES | $7,161 | $0 | Not Implemented |
OK0764 # 07 Y:2008 | 07 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $28,620 | $23,375 | Not Implemented |
OK0764 # 08 Y:2008 | 08 | 2008 | REDUCE EXCESSIVE BOILER BLOWDOWN | $2,877 | $0 | Not Implemented |
DL0012 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,593 | $26,675 | Implemented |
DL0012 # 02 Y:2008 | 02 | 2008 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $19,600 | $23,900 | Not Implemented |