Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,671
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0236 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $758 | $220 | Implemented |
SU0236 # 07 Y:2006 | 07 | 2006 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $65,227 | $70,000 | Implemented |
SU0236 # 08 Y:2006 | 08 | 2006 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,279 | $2,517 | Implemented |
SU0236 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $656 | $1,314 | Not Implemented |
SU0236 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,858 | $12,200 | Implemented |
SU0236 # 11 Y:2006 | 11 | 2006 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $4,046 | $8,856 | Not Implemented |
SU0236 # 12 Y:2006 | 12 | 2006 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $288 | $701 | Not Implemented |
SD0381 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,290 | $320 | Implemented |
SD0381 # 02 Y:2006 | 02 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,236 | $5,650 | Not Implemented |
SD0381 # 03 Y:2006 | 03 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,237 | $7,600 | Not Implemented |
SD0381 # 04 Y:2006 | 04 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $2,044 | $146 | Implemented |
SD0381 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,694 | $2,217 | Not Implemented |
SD0381 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $305 | $0 | Implemented |
NC0339 # 01 Y:2006 | 01 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $227,235 | $231,600 | Not Implemented |
NC0339 # 02 Y:2006 | 02 | 2006 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $675,393 | $100,000 | Not Implemented |
NC0339 # 03 Y:2006 | 03 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $41,056 | $10,000 | Implemented |
NC0339 # 04 Y:2006 | 04 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $93,691 | $100,000 | Implemented |
NC0339 # 05 Y:2006 | 05 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $64,630 | $11,200 | Not Implemented |
NC0339 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,853 | $20,000 | Implemented |
NC0339 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,136 | $1,407 | Implemented |
NC0339 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,369 | $50 | Implemented |
MI0130 # 01 Y:2006 | 01 | 2006 | REDESIGN PROCESS | $7,148 | $580 | Implemented |
MI0130 # 02 Y:2006 | 02 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,958 | $202 | Implemented |
MI0130 # 03 Y:2006 | 03 | 2006 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $4,791 | $1,020 | Implemented |
MI0130 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,865 | $1,074 | Implemented |