Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,415
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0360 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,405 | $0 | Not Implemented |
UF0360 # 07 Y:2005 | 07 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,246 | $6,221 | Implemented |
UF0360 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $585 | $332 | Not Implemented |
UF0360 # 09 Y:2005 | 09 | 2005 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $0 | $0 | Implemented |
SD0361 # 01 Y:2005 | 01 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,131 | $15,000 | Not Implemented |
SD0361 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,570 | $280 | Implemented |
SD0361 # 03 Y:2005 | 03 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,916 | $144 | Implemented |
SD0361 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $390 | $170 | Implemented |
SD0361 # 05 Y:2005 | 05 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $42,000 | $18,500 | Not Implemented |
OK0705 # 01 Y:2005 | 01 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,953 | $32,150 | Not Implemented |
OK0705 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $978 | $6,015 | Not Implemented |
OK0705 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,199 | $1,007 | Not Implemented |
OK0705 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,908 | $4,618 | Not Implemented |
OK0705 # 05 Y:2005 | 05 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,153 | $14,047 | Not Implemented |
OK0705 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $199 | $302 | Not Implemented |
OK0705 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $842 | $6,783 | Not Implemented |
OK0705 # 08 Y:2005 | 08 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,062 | $50,389 | Not Implemented |
NC0313 # 01 Y:2005 | 01 | 2005 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $9,148 | $15,000 | Not Implemented |
NC0313 # 02 Y:2005 | 02 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $17,625 | $50,000 | Not Implemented |
NC0313 # 03 Y:2005 | 03 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,261 | $2,000 | Implemented |
NC0313 # 04 Y:2005 | 04 | 2005 | USE MINIMUM STEAM OPERATING PRESSURE | $7,578 | $200 | Not Implemented |
NC0313 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $274 | $100 | Implemented |
LE0209 # 01 Y:2005 | 01 | 2005 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $669,800 | $350,000 | Not Implemented |
LE0209 # 02 Y:2005 | 02 | 2005 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $200,574 | $550,000 | Not Implemented |
LE0209 # 03 Y:2005 | 03 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $18,034 | $95 | Implemented |