Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,415

matching recommendations
Reset
NAICS 326 Plastics and Rubber Products Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0797 # 04 Y:2005 04 2005 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,210 $17,150 Not Implemented
GT0797 # 05 Y:2005 05 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,100 $500 Implemented
GT0797 # 06 Y:2005 06 2005 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $7,716 $400 Implemented
GT0797 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,447 $3,692 Implemented
SU0204 # 01 Y:2005 01 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,324 $0 Not Implemented
SU0204 # 02 Y:2005 02 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $938 $0 Not Implemented
SU0204 # 03 Y:2005 03 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $677 $0 Not Implemented
SU0204 # 04 Y:2005 04 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $175 $0 Implemented
SU0204 # 05 Y:2005 05 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,158 $344 Not Implemented
SU0204 # 06 Y:2005 06 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,236 $748 Not Implemented
SU0204 # 07 Y:2005 07 2005 USE SYNTHETIC LUBRICANT $3,145 $2,000 Implemented
SU0204 # 08 Y:2005 08 2005 OPTIMIZE PLANT POWER FACTOR $3,731 $11,931 Not Implemented
MI0098 # 01 Y:2005 01 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $24,731 $1,000 Implemented
MI0098 # 02 Y:2005 02 2005 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $7,463 $111 Implemented
MI0098 # 03 Y:2005 03 2005 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $4,950 $1,910 Implemented
MI0098 # 04 Y:2005 04 2005 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $2,754 $4,360 Not Implemented
MI0098 # 05 Y:2005 05 2005 REPAIR AND ELIMINATE STEAM LEAKS $901 $380 Implemented
MI0098 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $301 $400 Implemented
AS0391 # 01 Y:2005 01 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $71,356 $27,044 Not Implemented
AS0391 # 02 Y:2005 02 2005 UPGRADE CONTROLS ON COMPRESSORS $56,937 $10,000 Not Implemented
AS0391 # 03 Y:2005 03 2005 DEVELOP STANDARD OPERATING PROCEDURES $121,316 $80,000 Not Implemented
AS0391 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,082 $14,973 Not Implemented
AS0391 # 05 Y:2005 05 2005 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $14,058 $5,000 Not Implemented
AS0391 # 06 Y:2005 06 2005 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $14,162 $625 Not Implemented
AS0391 # 07 Y:2005 07 2005 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $11,974 $2,667 Not Implemented