Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
122
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0932 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $240 | $125 | Not Implemented |
OK0932 # 08 Y:2016 | 08 | 2016 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,679 | $12,315 | Not Implemented |
OK0932 # 09 Y:2016 | 09 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $429 | $0 | Not Implemented |
OK0932 # 10 Y:2016 | 10 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,093 | $30,000 | Not Implemented |
OK0932 # 11 Y:2016 | 11 | 2016 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $3,216 | $871 | Not Implemented |
OK0932 # 12 Y:2016 | 12 | 2016 | OPERATE BOILERS ON HIGH FIRE SETTING | $16,492 | $0 | Implemented |
OK0932 # 13 Y:2016 | 13 | 2016 | REPAIR AND ELIMINATE STEAM LEAKS | $4,272 | $1,100 | Implemented |
OK0932 # 14 Y:2016 | 14 | 2016 | SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE | $4,116 | $0 | Not Implemented |
MZ0190 # 01 Y:2015 | 01 | 2015 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $36,633 | $120,000 | Not Implemented |
MZ0190 # 02 Y:2015 | 02 | 2015 | CONDENSE OPERATION INTO ONE BUILDING | $12,608 | $0 | Not Implemented |
MZ0190 # 03 Y:2015 | 03 | 2015 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $20,868 | $40,000 | Not Implemented |
MZ0190 # 04 Y:2015 | 04 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,095 | $3,500 | Not Implemented |
MZ0190 # 05 Y:2015 | 05 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,663 | $1,500 | Not Implemented |
MZ0190 # 06 Y:2015 | 06 | 2015 | ELIMINATE/REDUCE AN OPERATION | $928 | $0 | Not Implemented |
MZ0190 # 07 Y:2015 | 07 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,483 | $860 | Implemented |
MZ0190 # 08 Y:2015 | 08 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,028 | $1,500 | Not Implemented |
OK0913 # 01 Y:2015 | 01 | 2015 | INSTALL OCCUPANCY SENSORS | $6,606 | $2,673 | Not Implemented |
OK0913 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,311 | $1,578 | Not Implemented |
OK0913 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,931 | $23,184 | Not Implemented |
OK0913 # 04 Y:2015 | 04 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $3,806 | $1,000 | Implemented |
OK0913 # 05 Y:2015 | 05 | 2015 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,525 | $9,000 | Not Implemented |
OK0913 # 06 Y:2015 | 06 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $1,330 | $85 | Not Implemented |
OK0913 # 07 Y:2015 | 07 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $399 | $133 | Implemented |
OK0913 # 08 Y:2015 | 08 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $137 | $0 | Not Implemented |
OK0886 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,646 | $17,062 | Not Implemented |