Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,415
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0252 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,568 | $3,999 | Implemented |
BD0258 # 01 Y:2004 | 01 | 2004 | INSTALL OCCUPANCY SENSORS | $2,506 | $2,025 | Implemented |
BD0258 # 02 Y:2004 | 02 | 2004 | INSTALL OCCUPANCY SENSORS | $953 | $2,175 | Implemented |
BD0258 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $952 | $1,280 | Implemented |
BD0258 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $611 | $600 | Implemented |
BD0258 # 05 Y:2004 | 05 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $575 | $24 | Not Implemented |
BD0258 # 06 Y:2004 | 06 | 2004 | INSTALL SPECTRAL REFLECTORS / DELAMP | $271 | $335 | Implemented |
BD0258 # 07 Y:2004 | 07 | 2004 | USE LESS WASTEFUL PACKAGING | $1,672 | $180 | Not Implemented |
MA0550 # 01 Y:2004 | 01 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $86,929 | $32,965 | Not Implemented |
MA0550 # 02 Y:2004 | 02 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,960 | $23,000 | Not Implemented |
MA0550 # 03 Y:2004 | 03 | 2004 | OPTIMIZE PLANT POWER FACTOR | $10,668 | $2,066 | Not Implemented |
MA0550 # 04 Y:2004 | 04 | 2004 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $599 | $0 | Not Implemented |
MA0550 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $547 | $0 | Not Implemented |
MA0550 # 06 Y:2004 | 06 | 2004 | INSULATE BARE EQUIPMENT | $185 | $120 | Not Implemented |
WV0287 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $9,905 | $479 | Implemented |
WV0287 # 02 Y:2004 | 02 | 2004 | SHUT OFF AIR CONDITIONING IN WINTER HEATING SEASON | $9,585 | $0 | Not Implemented |
WV0287 # 03 Y:2004 | 03 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,944 | $0 | Implemented |
WV0287 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $6,353 | $700 | Implemented |
WV0287 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,278 | $280 | Not Implemented |
WV0287 # 06 Y:2004 | 06 | 2004 | INSULATE BARE EQUIPMENT | $2,932 | $97 | Implemented |
WV0287 # 07 Y:2004 | 07 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $2,860 | $250 | Implemented |
WV0287 # 08 Y:2004 | 08 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,091 | $1,770 | Not Implemented |
WV0287 # 09 Y:2004 | 09 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,482 | $1,000 | Implemented |
WV0287 # 10 Y:2004 | 10 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $906 | $0 | Implemented |
WV0287 # 11 Y:2004 | 11 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $754 | $50 | Implemented |