IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,627

matching recommendations
Reset
NAICS 326 Plastics and Rubber Products Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UU0048 # 06 Y:2003 06 2003 REPAIR OR REPLACE STEAM TRAPS $16,294 $5,000 Not Implemented
UU0048 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $480 $0 Not Implemented
UU0048 # 08 Y:2003 08 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $493 $518 Not Implemented
UU0048 # 09 Y:2003 09 2003 RECOVER AND REUSE COOLING WATER $9,920 $7,907 Not Implemented
UU0048 # 10 Y:2003 10 2003 REUSE / RECYCLE/ SELL RUBBER PRODUCTS $1 $0 Not Implemented
NC0260 # 01 Y:2003 01 2003 INSTALL OCCUPANCY SENSORS $396 $208 Not Implemented
NC0260 # 02 Y:2003 02 2003 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $19,437 $8,000 Not Implemented
NC0260 # 03 Y:2003 03 2003 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $16,074 $9,000 Not Implemented
NC0260 # 04 Y:2003 04 2003 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $606 $176 Not Implemented
NC0260 # 05 Y:2003 05 2003 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $11,263 $16,548 Not Implemented
NC0260 # 06 Y:2003 06 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $234 $0 Not Implemented
NC0260 # 07 Y:2003 07 2003 DEVELOP A REPAIR/REPLACE POLICY $347 $260 Not Implemented
NC0260 # 08 Y:2003 08 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $264 $252 Not Implemented
NC0260 # 09 Y:2003 09 2003 USE PHOTOCELL CONTROLS $806 $550 Not Implemented
WV0271 # 01 Y:2003 01 2003 INSULATE BARE EQUIPMENT $76,401 $2,253 Implemented
WV0271 # 02 Y:2003 02 2003 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $27,875 $480 Implemented
WV0271 # 03 Y:2003 03 2003 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM $36,152 $180,000 Not Implemented
WV0271 # 04 Y:2003 04 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $13,169 $500 Not Implemented
WV0271 # 05 Y:2003 05 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,764 $128 Implemented
WV0271 # 06 Y:2003 06 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $4,697 $32 Not Implemented
WV0271 # 07 Y:2003 07 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $3,967 $1,741 Not Implemented
WV0271 # 08 Y:2003 08 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,612 $800 Not Implemented
WV0271 # 09 Y:2003 09 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,425 $250 Implemented
WV0271 # 10 Y:2003 10 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,758 $0 Implemented
WV0271 # 11 Y:2003 11 2003 INSTALL OCCUPANCY SENSORS $839 $800 Implemented