Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
247
matching recommendationsNAICS | 326 | Plastics and Rubber Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0343 # 03 Y:2008 | 03 | 2008 | USE OPTIMUM THICKNESS INSULATION | $8,476 | $9,576 | Not Implemented |
UM0343 # 04 Y:2008 | 04 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $3,750 | $0 | Implemented |
UM0343 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,390 | $5,864 | Not Implemented |
UM0343 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,378 | $750 | Implemented |
UM0325 # 01 Y:2007 | 01 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $56,621 | $14,400 | Implemented |
UM0325 # 02 Y:2007 | 02 | 2007 | REDUCE VENTILATION AIR | $22,071 | $17,000 | Not Implemented |
UM0325 # 03 Y:2007 | 03 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,908 | $3,000 | Not Implemented |
UM0325 # 04 Y:2007 | 04 | 2007 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $9,212 | $0 | Implemented |
UM0325 # 05 Y:2007 | 05 | 2007 | INSULATE BARE EQUIPMENT | $7,856 | $4,379 | Not Implemented |
UM0325 # 06 Y:2007 | 06 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,729 | $1,620 | Implemented |
UM0325 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,586 | $2,640 | Not Implemented |
UM0325 # 08 Y:2007 | 08 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,151 | $1,000 | Not Implemented |
UM0325 # 09 Y:2007 | 09 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $701 | $400 | Not Implemented |
UM0317 # 01 Y:2007 | 01 | 2007 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $24,281 | $50,000 | Implemented |
UM0317 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $14,750 | $1,970 | Implemented |
UM0317 # 03 Y:2007 | 03 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,819 | $1,700 | Not Implemented |
UM0317 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $9,662 | $6,000 | Implemented |
UM0317 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $3,666 | $828 | Implemented |
UM0317 # 06 Y:2007 | 06 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,456 | $100 | Not Implemented |
UM0317 # 07 Y:2007 | 07 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,378 | $410 | Not Implemented |
UM0265 # 01 Y:2004 | 01 | 2004 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $105,689 | $64,000 | n/a |
UM0265 # 02 Y:2004 | 02 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $30,525 | $30,000 | n/a |
UM0265 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,733 | $15,532 | n/a |
UM0265 # 04 Y:2004 | 04 | 2004 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $11,886 | $30,000 | n/a |
UM0265 # 05 Y:2004 | 05 | 2004 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $6,581 | $10,000 | n/a |