IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

763

matching recommendations
Reset
NAICS 3261 Plastics Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0868 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,026 $107,140 Not Implemented
UD0868 # 03 Y:2012 03 2012 INSTALL OCCUPANCY SENSORS $1,542 $1,350 Implemented
UD0868 # 04 Y:2012 04 2012 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,282 $0 Implemented
UD0868 # 05 Y:2012 05 2012 UPGRADE CONTROLS ON COMPRESSORS $2,154 $380 Not Implemented
UD0868 # 06 Y:2012 06 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,591 $2,000 Not Implemented
UD0868 # 07 Y:2012 07 2012 UPGRADE CONTROLS ON COMPRESSORS $682 $1,000 Implemented
UD0868 # 08 Y:2012 08 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,792 $1,000 Implemented
UD0868 # 09 Y:2012 09 2012 COVER OPEN TANKS $1,393 $800 Not Implemented
UD0868 # 10 Y:2012 10 2012 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,355 $2,415 Not Implemented
UD0868 # 11 Y:2012 11 2012 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $11,912 $5,400 Implemented
UD0868 # 12 Y:2012 12 2012 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $665 $2,000 Not Implemented
UD0867 # 01 Y:2012 01 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,897 $12,947 Implemented
UD0867 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,726 $35,503 Implemented
UD0867 # 03 Y:2012 03 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,088 $10,618 Implemented
UD0867 # 04 Y:2012 04 2012 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $8,831 $0 Not Implemented
UD0867 # 05 Y:2012 05 2012 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $20,787 $15,000 Not Implemented
UD0867 # 06 Y:2012 06 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,942 $1,000 Implemented
UD0867 # 07 Y:2012 07 2012 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $10,916 $0 Not Implemented
UD0867 # 08 Y:2012 08 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $8,474 $10,000 Not Implemented
UD0867 # 09 Y:2012 09 2012 UTILIZE A LESS EXPENSIVE COOLING METHOD $23,710 $0 Not Implemented
UD0867 # 10 Y:2012 10 2012 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,097 $0 Implemented
WV0443 # 01 Y:2012 01 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $186,348 $102,956 Not Implemented
WV0443 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $59,316 $160,057 Implemented
WV0443 # 03 Y:2012 03 2012 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $39,551 $6,000 Implemented
WV0443 # 04 Y:2012 04 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $30,777 $32,050 Not Implemented