Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,072
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0292 # 11 Y:2004 | 11 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,074 | $0 | Implemented |
WV0292 # 12 Y:2004 | 12 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,851 | $528 | Implemented |
WV0292 # 13 Y:2004 | 13 | 2004 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,626 | $750 | Implemented |
WV0292 # 14 Y:2004 | 14 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,330 | $420 | Implemented |
WV0292 # 15 Y:2004 | 15 | 2004 | INSTALL OCCUPANCY SENSORS | $1,326 | $1,048 | Implemented |
WV0292 # 16 Y:2004 | 16 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,014 | $100 | Implemented |
WV0292 # 17 Y:2004 | 17 | 2004 | KEEP LAMPS AND REFLECTORS CLEAN | $841 | $840 | Implemented |
WV0292 # 18 Y:2004 | 18 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $665 | $1,296 | Not Implemented |
WV0292 # 19 Y:2004 | 19 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $625 | $30 | Implemented |
WV0292 # 20 Y:2004 | 20 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $16,866 | $8,560 | Not Implemented |
WV0292 # 21 Y:2004 | 21 | 2004 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $13,489 | $4,460 | Not Implemented |
WV0292 # 22 Y:2004 | 22 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $8,249 | $1,200 | Implemented |
WV0292 # 23 Y:2004 | 23 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,043 | $459 | Not Implemented |
WV0292 # 24 Y:2004 | 24 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,935 | $5,740 | Not Implemented |
WV0292 # 25 Y:2004 | 25 | 2004 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,929 | $3,460 | Not Implemented |
WV0292 # 26 Y:2004 | 26 | 2004 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $4,494 | $4,715 | Implemented |
WV0292 # 27 Y:2004 | 27 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,007 | $1,000 | Implemented |
WV0292 # 28 Y:2004 | 28 | 2004 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $1,659 | $2,088 | Not Implemented |
WV0292 # 29 Y:2004 | 29 | 2004 | INSTALL OCCUPANCY SENSORS | $1,497 | $1,944 | Not Implemented |
SD0348 # 01 Y:2004 | 01 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $12,921 | $12,655 | Not Implemented |
SD0348 # 02 Y:2004 | 02 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,682 | $2,600 | Not Implemented |
SD0348 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,371 | $747 | Not Implemented |
SD0348 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $1,538 | $1,720 | Not Implemented |
SD0348 # 05 Y:2004 | 05 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,553 | $18,500 | Not Implemented |
SD0348 # 06 Y:2004 | 06 | 2004 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $70,166 | $43,083 | Not Implemented |