Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
266
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0143 # 02 Y:2008 | 02 | 2008 | DISCONNECT BALLASTS | $26 | $26 | Implemented |
IC0143 # 03 Y:2008 | 03 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $338 | $0 | Implemented |
IC0143 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $944 | $162 | Implemented |
IC0143 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $90 | $142 | Implemented |
IC0143 # 06 Y:2008 | 06 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,385 | $1,541 | Implemented |
IC0143 # 07 Y:2008 | 07 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,544 | $1,035 | Implemented |
IC0143 # 08 Y:2008 | 08 | 2008 | INSULATE BARE EQUIPMENT | $688 | $580 | Not Implemented |
IC0143 # 09 Y:2008 | 09 | 2008 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,040 | $37 | Implemented |
IC0143 # 10 Y:2008 | 10 | 2008 | INSULATE BARE EQUIPMENT | $50 | $42 | Not Implemented |
IC0143 # 11 Y:2008 | 11 | 2008 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,202 | $32,361 | Implemented |
IC0143 # 12 Y:2008 | 12 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $541 | $0 | Implemented |
IC0143 # 13 Y:2008 | 13 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $195 | $0 | Not Implemented |
WI0509 # 01 Y:2006 | 01 | 2006 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $34,120 | $25,000 | Not Implemented |
WI0509 # 02 Y:2006 | 02 | 2006 | USE CLEAN IN PLACE (CIP) SYSTEMS | $24,741 | $37,800 | Not Implemented |
WI0509 # 03 Y:2006 | 03 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $6,741 | $0 | Not Implemented |
WI0509 # 04 Y:2006 | 04 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,107 | $1,000 | Not Implemented |
WI0509 # 05 Y:2006 | 05 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,764 | $640 | Not Implemented |
WI0509 # 06 Y:2006 | 06 | 2006 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,330 | $0 | Not Implemented |
WI0509 # 07 Y:2006 | 07 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,189 | $0 | Not Implemented |
WI0509 # 08 Y:2006 | 08 | 2006 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,886 | $3,886 | Not Implemented |
WI0509 # 09 Y:2006 | 09 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $769 | $400 | Not Implemented |
WI0508 # 01 Y:2006 | 01 | 2006 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $147,000 | $0 | Not Implemented |
WI0508 # 02 Y:2006 | 02 | 2006 | IMPROVE SPACE COMFORT CONDITIONING | $30,404 | $5,200 | Not Implemented |
WI0508 # 03 Y:2006 | 03 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,872 | $0 | Not Implemented |
WI0508 # 04 Y:2006 | 04 | 2006 | USE SYNTHETIC LUBRICANT | $4,951 | $0 | Not Implemented |