Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
531
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0439 # 13 Y:2013 | 13 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,151 | $18,136 | Not Implemented |
SF0439 # 14 Y:2013 | 14 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $370 | $1,980 | Not Implemented |
SF0439 # 15 Y:2013 | 15 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $19,319 | $118,398 | Not Implemented |
SD0475 # 01 Y:2013 | 01 | 2013 | REDUCE SCRAP PRODUCTION | $478,006 | $153,240 | Not Implemented |
SD0475 # 02 Y:2013 | 02 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $74,589 | $105,000 | Not Implemented |
SD0475 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $72,583 | $20,000 | Not Implemented |
SD0475 # 04 Y:2013 | 04 | 2013 | INSULATE BARE EQUIPMENT | $38,801 | $8,131 | Not Implemented |
SD0475 # 05 Y:2013 | 05 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $32,247 | $22,575 | Not Implemented |
SD0475 # 06 Y:2013 | 06 | 2013 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $31,432 | $18,685 | Not Implemented |
SD0475 # 07 Y:2013 | 07 | 2013 | USE POWER DURING OFF-PEAK PERIODS | $14,075 | $28,900 | Implemented |
SD0475 # 08 Y:2013 | 08 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,799 | $24,000 | Not Implemented |
SD0475 # 09 Y:2013 | 09 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,883 | $30,800 | Implemented |
SD0475 # 10 Y:2013 | 10 | 2013 | USE PHOTOCELL CONTROLS | $3,183 | $3,515 | Implemented |
SD0475 # 11 Y:2013 | 11 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,517 | $4,185 | Not Implemented |
SD0475 # 12 Y:2013 | 12 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $1,418 | $1,750 | Not Implemented |
SD0474 # 01 Y:2013 | 01 | 2013 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $404,689 | $1,152,300 | Not Implemented |
SD0474 # 02 Y:2013 | 02 | 2013 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $47,675 | $150,500 | Not Implemented |
SD0474 # 03 Y:2013 | 03 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $44,050 | $30,000 | Not Implemented |
SD0474 # 04 Y:2013 | 04 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $40,480 | $35,200 | Implemented |
SD0474 # 05 Y:2013 | 05 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $37,276 | $40,200 | Implemented |
SD0474 # 06 Y:2013 | 06 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $23,678 | $87,264 | Not Implemented |
SD0474 # 07 Y:2013 | 07 | 2013 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $15,779 | $45,500 | Not Implemented |
SD0474 # 08 Y:2013 | 08 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,576 | $16,500 | Not Implemented |
SD0474 # 09 Y:2013 | 09 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,172 | $5,250 | Implemented |
SD0474 # 10 Y:2013 | 10 | 2013 | USE PHOTOCELL CONTROLS | $2,088 | $7,400 | Implemented |