Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
87
matching recommendationsNAICS | 3261 | Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0308 # 01 Y:2021 | 01 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,438 | $24,586 | Not Implemented |
MZ0308 # 03 Y:2021 | 03 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,047 | $1,210 | Not Implemented |
MZ0308 # 02 Y:2021 | 02 | 2021 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,647 | $5,300 | Not Implemented |
MZ0278 # 10 Y:2019 | 10 | 2019 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,709 | $200 | Implemented |
MZ0278 # 04 Y:2019 | 04 | 2019 | REDUCE SCRAP PRODUCTION | $126,263 | $207,500 | Implemented |
MZ0278 # 03 Y:2019 | 03 | 2019 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $176,232 | $3,250 | Implemented |
MZ0278 # 02 Y:2019 | 02 | 2019 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $382,507 | $601,250 | Implemented |
MZ0278 # 01 Y:2019 | 01 | 2019 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $902,475 | $6,762,500 | Implemented |
MZ0278 # 07 Y:2019 | 07 | 2019 | UPGRADE CONTROLS ON COMPRESSORS | $42,284 | $13,051 | Implemented |
MZ0278 # 08 Y:2019 | 08 | 2019 | RECOVER WASTE HEAT FROM EQUIPMENT | $35,571 | $11,900 | Not Implemented |
MZ0278 # 06 Y:2019 | 06 | 2019 | INSULATE BARE EQUIPMENT | $45,917 | $2,907 | Implemented |
MZ0278 # 09 Y:2019 | 09 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,558 | $870 | Implemented |
MZ0278 # 05 Y:2019 | 05 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $53,880 | $7,750 | Not Implemented |
MZ0247 # 03 Y:2018 | 03 | 2018 | INSTALL OCCUPANCY SENSORS | $6,231 | $2,346 | Implemented |
MZ0247 # 07 Y:2018 | 07 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,794 | $740 | Not Implemented |
MZ0247 # 06 Y:2018 | 06 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,053 | $170 | Not Implemented |
MZ0247 # 05 Y:2018 | 05 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,573 | $500 | Not Implemented |
MZ0247 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,430 | $4,900 | Implemented |
MZ0247 # 02 Y:2018 | 02 | 2018 | OPTIMIZE PLANT POWER FACTOR | $13,764 | $10,000 | Not Implemented |
MZ0247 # 01 Y:2018 | 01 | 2018 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $29,241 | $3,340 | Not Implemented |
MZ0235 # 08 Y:2017 | 08 | 2017 | INSTALL OCCUPANCY SENSORS | $601 | $1,362 | Not Implemented |
MZ0235 # 07 Y:2017 | 07 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $933 | $300 | Implemented |
MZ0235 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $941 | $2,999 | Not Implemented |
MZ0235 # 05 Y:2017 | 05 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,640 | $1,000 | Implemented |
MZ0235 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,101 | $1,623 | Implemented |