Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

928

matching recommendations
Reset
NAICS 32612 Plastics Pipe, Pipe Fitting, and Unlaminated Profile Shape Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0460 # 02 Y:2013 02 2013 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $14,224 $1,000 Implemented
WV0460 # 03 Y:2013 03 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,833 $27,115 Not Implemented
WV0460 # 11 Y:2013 11 2013 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $737 $829 Implemented
WV0460 # 10 Y:2013 10 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $797 $1,725 Implemented
WV0460 # 09 Y:2013 09 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $936 $10,030 Implemented
WV0460 # 08 Y:2013 08 2013 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $1,354 $6,500 Not Implemented
WV0460 # 07 Y:2013 07 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,232 $18 Implemented
WV0460 # 06 Y:2013 06 2013 INSTALL TIMERS AND/OR THERMOSTATS $2,480 $2,088 Not Implemented
WV0460 # 04 Y:2013 04 2013 DEVELOP A REPAIR/REPLACE POLICY $7,221 $553 Implemented
UD0844 # 01 Y:2011 01 2011 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $170,257 $280,000 Not Implemented
UD0844 # 02 Y:2011 02 2011 USE REACTIVE RINSING $70,989 $30,000 Not Implemented
UD0844 # 03 Y:2011 03 2011 OPTIMIZE PLANT POWER FACTOR $11,543 $16,000 Not Implemented
UD0844 # 04 Y:2011 04 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $33,247 $2,000 Not Implemented
UD0844 # 05 Y:2011 05 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,557 $0 Implemented
UD0844 # 06 Y:2011 06 2011 UPGRADE CONTROLS ON COMPRESSORS $20,051 $18,555 Not Implemented
UD0844 # 07 Y:2011 07 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,542 $0 Not Implemented
UD0844 # 08 Y:2011 08 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,988 $5,000 Not Implemented
UD0844 # 09 Y:2011 09 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,616 $500 Not Implemented
UD0844 # 10 Y:2011 10 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $267 $0 Implemented
UD0844 # 11 Y:2011 11 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,123 $1,000 Implemented
UD0844 # 12 Y:2011 12 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $10,508 $16,000 Not Implemented
UD0844 # 13 Y:2011 13 2011 USE OPTIMUM TEMPERATURE $3,225 $0 Not Implemented
UD0844 # 14 Y:2011 14 2011 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $18,762 $0 Implemented
UD0844 # 15 Y:2011 15 2011 REDUCE VENTILATION AIR $17,779 $0 Not Implemented
UM0390 # 01 Y:2011 01 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $16,753 $200 Not Implemented