IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,921

matching recommendations
Reset
NAICS 32619 Other Plastics Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0390 # 13 Y:2010 13 2010 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $39,251 $58,106 Implemented
SF0390 # 14 Y:2010 14 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $846 $1,500 Not Implemented
SF0390 # 15 Y:2010 15 2010 USE PHOTOCELL CONTROLS $1,030 $2,587 Implemented
SF0390 # 16 Y:2010 16 2010 INSTALL OCCUPANCY SENSORS $2,946 $75 Not Implemented
SF0390 # 17 Y:2010 17 2010 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $6,167 $17,310 Not Implemented
SF0390 # 18 Y:2010 18 2010 OPTIMIZE PLANT POWER FACTOR $5,696 $21,908 Implemented
DL0060 # 01 Y:2010 01 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $65,458 $79,125 Not Implemented
DL0060 # 02 Y:2010 02 2010 INSULATE BARE EQUIPMENT $12,645 $14,080 Not Implemented
DL0060 # 03 Y:2010 03 2010 INSTALL OCCUPANCY SENSORS $2,705 $422 Not Implemented
DL0060 # 04 Y:2010 04 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,957 $26,400 Implemented
DL0060 # 05 Y:2010 05 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,557 $8,750 Not Implemented
DL0060 # 06 Y:2010 06 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,362 $21,600 Implemented
UM0374 # 01 Y:2010 01 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,667 $200 Not Implemented
UM0374 # 02 Y:2010 02 2010 INSTALL OCCUPANCY SENSORS $1,765 $2,250 Not Implemented
UM0374 # 03 Y:2010 03 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,227 $6,400 Not Implemented
UM0374 # 04 Y:2010 04 2010 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $15,389 $33,705 Not Implemented
UM0374 # 05 Y:2010 05 2010 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $10,662 $40,550 Not Implemented
UM0374 # 06 Y:2010 06 2010 RECOVER WASTE HEAT FROM EQUIPMENT $10,185 $10,900 Implemented
UM0374 # 07 Y:2010 07 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $257 $93 Implemented
TT0055 # 01 Y:2010 01 2010 REDUCE VENTILATION AIR $5,009 $17,120 Not Implemented
TT0055 # 02 Y:2010 02 2010 OPTIMIZE PLANT POWER FACTOR $11,430 $13,000 Implemented
TT0055 # 03 Y:2010 03 2010 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $560 $825 Implemented
TT0055 # 04 Y:2010 04 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $1,500 $632 Not Implemented
TT0055 # 05 Y:2010 05 2010 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $520 $15 Implemented
TT0055 # 06 Y:2010 06 2010 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $253 $250 Implemented