Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,921
matching recommendationsNAICS | 32619 | Other Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0390 # 13 Y:2010 | 13 | 2010 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $39,251 | $58,106 | Implemented |
SF0390 # 14 Y:2010 | 14 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $846 | $1,500 | Not Implemented |
SF0390 # 15 Y:2010 | 15 | 2010 | USE PHOTOCELL CONTROLS | $1,030 | $2,587 | Implemented |
SF0390 # 16 Y:2010 | 16 | 2010 | INSTALL OCCUPANCY SENSORS | $2,946 | $75 | Not Implemented |
SF0390 # 17 Y:2010 | 17 | 2010 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $6,167 | $17,310 | Not Implemented |
SF0390 # 18 Y:2010 | 18 | 2010 | OPTIMIZE PLANT POWER FACTOR | $5,696 | $21,908 | Implemented |
DL0060 # 01 Y:2010 | 01 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $65,458 | $79,125 | Not Implemented |
DL0060 # 02 Y:2010 | 02 | 2010 | INSULATE BARE EQUIPMENT | $12,645 | $14,080 | Not Implemented |
DL0060 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,705 | $422 | Not Implemented |
DL0060 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,957 | $26,400 | Implemented |
DL0060 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,557 | $8,750 | Not Implemented |
DL0060 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,362 | $21,600 | Implemented |
UM0374 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,667 | $200 | Not Implemented |
UM0374 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $1,765 | $2,250 | Not Implemented |
UM0374 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,227 | $6,400 | Not Implemented |
UM0374 # 04 Y:2010 | 04 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $15,389 | $33,705 | Not Implemented |
UM0374 # 05 Y:2010 | 05 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $10,662 | $40,550 | Not Implemented |
UM0374 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,185 | $10,900 | Implemented |
UM0374 # 07 Y:2010 | 07 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $257 | $93 | Implemented |
TT0055 # 01 Y:2010 | 01 | 2010 | REDUCE VENTILATION AIR | $5,009 | $17,120 | Not Implemented |
TT0055 # 02 Y:2010 | 02 | 2010 | OPTIMIZE PLANT POWER FACTOR | $11,430 | $13,000 | Implemented |
TT0055 # 03 Y:2010 | 03 | 2010 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $560 | $825 | Implemented |
TT0055 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,500 | $632 | Not Implemented |
TT0055 # 05 Y:2010 | 05 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $520 | $15 | Implemented |
TT0055 # 06 Y:2010 | 06 | 2010 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $253 | $250 | Implemented |