Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,921
matching recommendationsNAICS | 32619 | Other Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0446 # 23 Y:2009 | 23 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,312 | $2,060 | Implemented |
GT0869 # 01 Y:2009 | 01 | 2009 | REPAIR AND ELIMINATE STEAM LEAKS | $7,130 | $2,100 | Implemented |
GT0869 # 02 Y:2009 | 02 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $352 | $0 | Implemented |
GT0869 # 03 Y:2009 | 03 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,117 | $890 | Implemented |
GT0869 # 04 Y:2009 | 04 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,201 | $900 | Not Implemented |
GT0869 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,586 | $42,920 | Implemented |
GT0869 # 06 Y:2009 | 06 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,715 | $17,250 | Not Implemented |
GT0869 # 07 Y:2009 | 07 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,291 | $4,515 | Not Implemented |
TT0043 # 01 Y:2009 | 01 | 2009 | Reduction | $5,562 | $2,500 | Implemented |
TT0043 # 02 Y:2009 | 02 | 2009 | Hardware | $11,711 | $300 | Implemented |
TT0043 # 03 Y:2009 | 03 | 2009 | Close Cycle Water Use | $2,148 | $2,568 | Implemented |
TT0043 # 04 Y:2009 | 04 | 2009 | Miscellaneous | $5,441 | $0 | Not Implemented |
TT0043 # 05 Y:2009 | 05 | 2009 | Hardware | $3,007 | $1,395 | Implemented |
UM0354 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,576 | $69,141 | Not Implemented |
UM0354 # 02 Y:2009 | 02 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $17,778 | $8,750 | Implemented |
UM0354 # 03 Y:2009 | 03 | 2009 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $13,567 | $9,570 | Implemented |
UM0354 # 04 Y:2009 | 04 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $12,144 | $4,200 | Implemented |
UM0354 # 05 Y:2009 | 05 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,488 | $0 | Not Implemented |
UM0354 # 06 Y:2009 | 06 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,114 | $500 | Implemented |
UM0354 # 07 Y:2009 | 07 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $983 | $200 | Implemented |
LE0287 # 01 Y:2009 | 01 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $184,606 | $250,000 | Not Implemented |
LE0287 # 02 Y:2009 | 02 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $220,823 | $50,000 | Not Implemented |
LE0287 # 03 Y:2009 | 03 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $79,515 | $8,000 | Not Implemented |
LE0287 # 04 Y:2009 | 04 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $36,003 | $650 | Not Implemented |
LE0287 # 05 Y:2009 | 05 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $19,644 | $17,000 | Not Implemented |