Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
101
matching recommendationsNAICS | 32619 | Other Plastics Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1804 # 11 Y:2018 | 11 | 2018 | INSULATE BARE EQUIPMENT | $1,814 | $704 | n/a |
UK1804 # 12 Y:2018 | 12 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $493 | $1,150 | n/a |
UK1804 # 13 Y:2018 | 13 | 2018 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $24,936 | $117,925 | n/a |
UK1804 # 14 Y:2018 | 14 | 2018 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,393 | $1,316 | n/a |
UK1804 # 15 Y:2018 | 15 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $681 | $0 | n/a |
UK1707 # 01 Y:2017 | 01 | 2017 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $1,711,450 | $2,189,000 | Implemented |
UK1707 # 02 Y:2017 | 02 | 2017 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,257 | $900 | Implemented |
UK1707 # 03 Y:2017 | 03 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $126,536 | $517,575 | Not Implemented |
UK1707 # 04 Y:2017 | 04 | 2017 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $15,886 | $11,500 | Implemented |
UK1707 # 05 Y:2017 | 05 | 2017 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $2,584 | $6,427 | Implemented |
UK1707 # 06 Y:2017 | 06 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $351 | $0 | Not Implemented |
UK1707 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $99,925 | $62,274 | Implemented |
UK1707 # 08 Y:2017 | 08 | 2017 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $11,723 | $18,000 | Not Implemented |
UK1707 # 09 Y:2017 | 09 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,235 | $2,650 | Implemented |
UK1707 # 10 Y:2017 | 10 | 2017 | OPTIMIZE PLANT POWER FACTOR | $81,973 | $62,685 | Implemented |
UK1707 # 11 Y:2017 | 11 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $34,216 | $0 | Implemented |
UK1707 # 12 Y:2017 | 12 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,296 | $2,550 | Implemented |
UK1707 # 13 Y:2017 | 13 | 2017 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $3,838 | $9,700 | Not Implemented |
UK1707 # 14 Y:2017 | 14 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,084 | $1,300 | Not Implemented |
UK1707 # 15 Y:2017 | 15 | 2017 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,522 | $1,400 | Not Implemented |
UK1707 # 16 Y:2017 | 16 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,352 | $0 | Not Implemented |
UK1707 # 17 Y:2017 | 17 | 2017 | REDUCE FLUID FLOW RATES | $7,372 | $0 | Not Implemented |
UK1707 # 18 Y:2017 | 18 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,373 | $0 | Not Implemented |
UK1707 # 19 Y:2017 | 19 | 2017 | INSULATE BARE EQUIPMENT | $2,802 | $2,100 | Not Implemented |
UK1504 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $49,404 | $93,500 | Not Implemented |