Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,921

matching recommendations
Reset
NAICS 32619 Other Plastics Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0527 # 04 Y:2014 04 2014 USE PHOTOCELL CONTROLS $1,490 $810 Not Implemented
IA0527 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,000 $2,939 Not Implemented
IA0527 # 06 Y:2014 06 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $577 $1,116 Not Implemented
IA0527 # 07 Y:2014 07 2014 INSTALL SPECTRAL REFLECTORS / DELAMP $646 $210 Not Implemented
IA0527 # 08 Y:2014 08 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $274 $75 Not Implemented
SU0367 # 01 Y:2014 01 2014 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $3,785 $0 Not Implemented
SU0367 # 02 Y:2014 02 2014 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,155 $0 Not Implemented
SU0367 # 03 Y:2014 03 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,427 $100 Implemented
SU0367 # 04 Y:2014 04 2014 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,111 $527 Not Implemented
SU0367 # 05 Y:2014 05 2014 INSTALL OCCUPANCY SENSORS $320 $100 Implemented
SU0367 # 06 Y:2014 06 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $913 $646 Not Implemented
SU0367 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $712 $582 Implemented
SU0367 # 08 Y:2014 08 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,369 $3,256 Not Implemented
SU0367 # 09 Y:2014 09 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,775 $6,702 Not Implemented
SU0367 # 10 Y:2014 10 2014 UPGRADE OBSOLETE EQUIPMENT $263 $1,078 Implemented
IP0028 # 01 Y:2014 01 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $545 $0 Implemented
IP0028 # 02 Y:2014 02 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $216 $13 Implemented
IP0028 # 03 Y:2014 03 2014 INSTALL SET-BACK TIMERS $1,201 $196 Implemented
IP0028 # 04 Y:2014 04 2014 INSTALL OCCUPANCY SENSORS $147 $76 Implemented
IP0028 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $282 $357 Implemented
IP0028 # 06 Y:2014 06 2014 INSULATE BARE EQUIPMENT $655 $2,312 Not Implemented
IP0028 # 07 Y:2014 07 2014 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $1,354 $5,025 Not Implemented
AM0662 # 01 Y:2014 01 2014 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $72,800 $26,790 Implemented
AM0662 # 02 Y:2014 02 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $44,492 $23,175 Implemented
AM0662 # 03 Y:2014 03 2014 PAY UTILITY BILLS ON TIME $18,665 $0 Implemented