Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

486

matching recommendations
Reset
NAICS 326199 All Other Plastics Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0816 # 12 Y:2010 12 2010 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,512 $0 Implemented
UD0816 # 13 Y:2010 13 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,524 $0 Not Implemented
UD0816 # 14 Y:2010 14 2010 INSTALL TIMERS AND/OR THERMOSTATS $10,027 $0 Not Implemented
UD0816 # 15 Y:2010 15 2010 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $1,123 $0 Not Implemented
UD0816 # 16 Y:2010 16 2010 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $766 $0 Not Implemented
UD0809 # 01 Y:2009 01 2009 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $22,565 $5,640 Implemented
UD0809 # 02 Y:2009 02 2009 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $20,495 $120,000 Implemented
UD0809 # 03 Y:2009 03 2009 OPTIMIZE PLANT POWER FACTOR $15,628 $20,000 Not Implemented
UD0809 # 04 Y:2009 04 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $8,423 $0 Implemented
UD0809 # 05 Y:2009 05 2009 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,288 $324 Not Implemented
UD0809 # 06 Y:2009 06 2009 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,845 $1,000 Not Implemented
UD0809 # 07 Y:2009 07 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $4,812 $0 Not Implemented
UD0809 # 08 Y:2009 08 2009 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $4,116 $23,400 Implemented
UD0809 # 09 Y:2009 09 2009 INSULATE BARE EQUIPMENT $2,822 $1,440 Not Implemented
UD0809 # 10 Y:2009 10 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,765 $1,048 Implemented
UD0809 # 11 Y:2009 11 2009 ELIMINATE LEAKS IN WATER LINES AND VALVES $1,858 $480 Not Implemented
UD0809 # 12 Y:2009 12 2009 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,411 $8,270 Not Implemented
UD0809 # 13 Y:2009 13 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,348 $1,703 Implemented
UD0809 # 14 Y:2009 14 2009 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $2,678 $5,467 Not Implemented
UD0809 # 15 Y:2009 15 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $685 $0 Not Implemented
UD0809 # 16 Y:2009 16 2009 DISCONNECT BALLASTS $532 $0 Not Implemented
UD0809 # 17 Y:2009 17 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $414 $0 Implemented
UD0809 # 18 Y:2009 18 2009 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $363 $0 Not Implemented
UD0809 # 19 Y:2009 19 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $181 $500 Not Implemented
UD0791 # 01 Y:2009 01 2009 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $180,324 $20,000 Implemented