IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,856

matching recommendations
Reset
NAICS 326199 All Other Plastics Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0395 # 06 Y:2007 06 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $659 $1,146 Not Implemented
AM0531 # 01 Y:2007 01 2007 SCHEDULE DELIVERIES ACCORDING TO DEMAND $460,000 $15,000 Implemented
AM0531 # 02 Y:2007 02 2007 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $7,000 $100 Not Implemented
AM0531 # 03 Y:2007 03 2007 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $25,140 $2,520 Not Implemented
AM0531 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,800 $8,680 Not Implemented
AM0531 # 05 Y:2007 05 2007 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $11,400 $1,140 Not Implemented
AM0531 # 06 Y:2007 06 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $825 $320 Implemented
AM0531 # 07 Y:2007 07 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $690 $140 Implemented
AM0531 # 08 Y:2007 08 2007 PAY UTILITY BILLS ON TIME $308 $0 Not Implemented
AM0531 # 09 Y:2007 09 2007 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $121 $0 Not Implemented
DL0001 # 01 Y:2007 01 2007 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $93,802 $111,140 Not Implemented
DL0001 # 02 Y:2007 02 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $12,151 $13,790 Implemented
DL0001 # 03 Y:2007 03 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $59,111 $104,392 Implemented
DL0001 # 04 Y:2007 04 2007 INSULATE BARE EQUIPMENT $44,733 $12,474 Not Implemented
DL0001 # 05 Y:2007 05 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,582 $620 Not Implemented
DL0001 # 06 Y:2007 06 2007 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $29,521 $0 Not Implemented
DL0001 # 07 Y:2007 07 2007 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $2,976 $5,832 Not Implemented
IA0405 # 01 Y:2007 01 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,619 $100 Implemented
IA0405 # 02 Y:2007 02 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,837 $500 Implemented
IA0405 # 03 Y:2007 03 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,667 $19,110 Not Implemented
IA0405 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,224 $2,791 Implemented
IA0405 # 05 Y:2007 05 2007 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,324 $238 Implemented
IA0405 # 06 Y:2007 06 2007 OPTIMIZE PLANT POWER FACTOR $4,587 $300 Implemented
IA0405 # 07 Y:2007 07 2007 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,458 $125 Implemented
IA0405 # 08 Y:2007 08 2007 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $2,837 $800 Implemented