Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,343
matching recommendationsNAICS | 3262 | Rubber Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0940 # 07 Y:2016 | 07 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,268 | $4,752 | Not Implemented |
OK0940 # 08 Y:2016 | 08 | 2016 | OPTIMIZE PLANT POWER FACTOR | $5,900 | $38,500 | Not Implemented |
OK0940 # 09 Y:2016 | 09 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,700 | $1,000 | Implemented |
NC0565 # 01 Y:2016 | 01 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,449 | $20,000 | Not Implemented |
NC0565 # 02 Y:2016 | 02 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $512 | $450 | Not Implemented |
NC0565 # 03 Y:2016 | 03 | 2016 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $17,784 | $500 | Not Implemented |
NC0565 # 04 Y:2016 | 04 | 2016 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,933 | $34,000 | Not Implemented |
NC0565 # 05 Y:2016 | 05 | 2016 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,805 | $10,500 | Not Implemented |
NC0565 # 06 Y:2016 | 06 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,968 | $5,000 | Not Implemented |
NC0565 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,126 | $200 | Not Implemented |
NC0565 # 08 Y:2016 | 08 | 2016 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $4,233 | $20,700 | Not Implemented |
NC0565 # 09 Y:2016 | 09 | 2016 | INSULATE BARE EQUIPMENT | $764 | $431 | Not Implemented |
NC0565 # 10 Y:2016 | 10 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $288 | $70 | Not Implemented |
NC0565 # 11 Y:2016 | 11 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,001 | $26,800 | Not Implemented |
NC0565 # 12 Y:2016 | 12 | 2016 | INSTALL OCCUPANCY SENSORS | $1,394 | $521 | Not Implemented |
NC0565 # 13 Y:2016 | 13 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,483 | $19,695 | Not Implemented |
NC0565 # 14 Y:2016 | 14 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,028 | $6,967 | Not Implemented |
NC0565 # 15 Y:2016 | 15 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $547 | $1,540 | Not Implemented |
NC0565 # 16 Y:2016 | 16 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $710 | $192 | Not Implemented |
NC0565 # 17 Y:2016 | 17 | 2016 | USE PHOTOCELL CONTROLS | $93 | $200 | Not Implemented |
NC0565 # 18 Y:2016 | 18 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $2,232 | $4,256 | Not Implemented |
NC0565 # 19 Y:2016 | 19 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,859 | $230 | Not Implemented |
MI0292 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38,353 | $95,355 | Implemented |
MI0292 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $30,595 | $1,660 | Implemented |
MI0292 # 03 Y:2016 | 03 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,974 | $40 | Not Implemented |