Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,343
matching recommendationsNAICS | 3262 | Rubber Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0399 # 03 Y:2010 | 03 | 2010 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $40,261 | $0 | Not Implemented |
NC0399 # 04 Y:2010 | 04 | 2010 | INSULATE BARE EQUIPMENT | $1,429 | $5,438 | Implemented |
NC0399 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,471 | $0 | Implemented |
NC0399 # 06 Y:2010 | 06 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $7,151 | $23,576 | Implemented |
NC0399 # 07 Y:2010 | 07 | 2010 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $6,943 | $8,852 | Not Implemented |
NC0399 # 08 Y:2010 | 08 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,744 | $1,550 | Implemented |
NC0399 # 09 Y:2010 | 09 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,805 | $6,000 | Implemented |
NC0399 # 10 Y:2010 | 10 | 2010 | INSULATE BARE EQUIPMENT | $1,592 | $2,600 | Implemented |
DL0046 # 01 Y:2010 | 01 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,503 | $0 | Not Implemented |
DL0046 # 02 Y:2010 | 02 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,940 | $0 | Not Implemented |
DL0046 # 03 Y:2010 | 03 | 2010 | INSULATE BARE EQUIPMENT | $7,292 | $520 | Not Implemented |
DL0046 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,168 | $1,500 | Implemented |
DL0046 # 05 Y:2010 | 05 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,619 | $10,000 | Implemented |
DL0046 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,295 | $23,738 | Implemented |
DL0046 # 07 Y:2010 | 07 | 2010 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $785 | $2,410 | Not Implemented |
MZ0036 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,757 | $26,855 | Implemented |
MZ0036 # 02 Y:2009 | 02 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,645 | $1,500 | Not Implemented |
MZ0036 # 03 Y:2009 | 03 | 2009 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $2,267 | $5,320 | Not Implemented |
MZ0036 # 04 Y:2009 | 04 | 2009 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $4,395 | $8,757 | Implemented |
MZ0036 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $62,000 | $850 | Implemented |
IA0441 # 01 Y:2009 | 01 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,701 | $680 | Not Implemented |
IA0441 # 02 Y:2009 | 02 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,759 | $17,051 | Not Implemented |
IA0441 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,444 | $702 | Implemented |
IA0441 # 04 Y:2009 | 04 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,935 | $825 | Not Implemented |
IA0441 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,456 | $650 | Not Implemented |