Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,343
matching recommendationsNAICS | 3262 | Rubber Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0561 # 06 Y:2004 | 06 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,473 | $2,750 | Implemented |
BD0268 # 01 Y:2004 | 01 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $352,557 | $1,500,000 | Implemented |
BD0268 # 02 Y:2004 | 02 | 2004 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $81,415 | $130,000 | Implemented |
BD0268 # 03 Y:2004 | 03 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $40,434 | $49,000 | Implemented |
BD0268 # 04 Y:2004 | 04 | 2004 | HEAT WATER WITH EXHAUST HEAT | $31,790 | $35,000 | Implemented |
BD0268 # 05 Y:2004 | 05 | 2004 | ADD AREA LIGHTING SWITCHES | $14,266 | $9,000 | Not Implemented |
BD0268 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,170 | $200 | Implemented |
BD0268 # 07 Y:2004 | 07 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,701 | $1,500 | Implemented |
BD0268 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $784 | $1,320 | Not Implemented |
BD0268 # 09 Y:2004 | 09 | 2004 | USE PHOTOCELL CONTROLS | $605 | $240 | Not Implemented |
BD0268 # 10 Y:2004 | 10 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $461 | $20 | Implemented |
BD0268 # 11 Y:2004 | 11 | 2004 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $15,653 | $6,914 | Implemented |
BD0268 # 12 Y:2004 | 12 | 2004 | USE LESS WASTEFUL PACKAGING | $1,586 | $3,600 | Implemented |
BD0268 # 13 Y:2004 | 13 | 2004 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $861 | $173 | Implemented |
AS0388 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $50,081 | $440 | Implemented |
AS0388 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $1,489 | $815 | Not Implemented |
AS0388 # 03 Y:2004 | 03 | 2004 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $366 | $1,530 | Not Implemented |
AS0388 # 04 Y:2004 | 04 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $283 | $800 | Not Implemented |
AS0388 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,196 | $1,247 | Not Implemented |
AS0388 # 06 Y:2004 | 06 | 2004 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $953 | $1,400 | Not Implemented |
AS0388 # 07 Y:2004 | 07 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,505 | $1,477 | Not Implemented |
WV0299 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $10,724 | $2,060 | Implemented |
WV0299 # 02 Y:2004 | 02 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,651 | $16,100 | Implemented |
WV0299 # 03 Y:2004 | 03 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,725 | $1,000 | Implemented |
WV0299 # 04 Y:2004 | 04 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,783 | $1,937 | Implemented |