matching recommendationsNAICS | 326211 | Tire Manufacturing (except Retreading) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0085 # 02 Y:2012 | 02 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $164,656 | $57,024 | Implemented |
UA0085 # 03 Y:2012 | 03 | 2012 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $86,957 | $214,808 | Not Implemented |
UA0085 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,936 | $7,682 | Not Implemented |
UA0085 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $151,364 | $35,390 | Implemented |
UA0085 # 06 Y:2012 | 06 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $146,229 | $68,100 | Not Implemented |
UA0085 # 07 Y:2012 | 07 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $58,443 | $1,920 | Implemented |
UA0085 # 08 Y:2012 | 08 | 2012 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $48,968 | $131,587 | Not Implemented |
UA0085 # 09 Y:2012 | 09 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $349,571 | $177,363 | Not Implemented |
UA0085 # 10 Y:2012 | 10 | 2012 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $529,960 | $400,000 | Not Implemented |
SU0318 # 01 Y:2012 | 01 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,626 | $0 | Not Implemented |
SU0318 # 02 Y:2012 | 02 | 2012 | USE SYNTHETIC LUBRICANT | $7,917 | $0 | Implemented |
SU0318 # 03 Y:2012 | 03 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $72 | $0 | Implemented |
SU0318 # 04 Y:2012 | 04 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $106,547 | $32,436 | Implemented |
SU0318 # 05 Y:2012 | 05 | 2012 | ELIMINATE/REDUCE AN OPERATION | $12,250 | $11,115 | Not Implemented |
SU0318 # 06 Y:2012 | 06 | 2012 | REDUCE VENTILATION AIR | $3,491 | $4,419 | Not Implemented |
SU0318 # 07 Y:2012 | 07 | 2012 | OPTIMIZE PLANT POWER FACTOR | $162,692 | $408,153 | Implemented |
SU0318 # 08 Y:2012 | 08 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $812 | $3,107 | Not Implemented |
SU0318 # 09 Y:2012 | 09 | 2012 | UPGRADE OBSOLETE EQUIPMENT | $211 | $795 | Implemented |
MS0378 # 01 Y:2011 | 01 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $23,582 | $178,700 | Not Implemented |
MS0378 # 02 Y:2011 | 02 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $14,148 | $132,820 | Not Implemented |
LL0289 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $274,767 | $187,520 | Implemented |
LL0289 # 02 Y:2008 | 02 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $110,300 | $3,650 | Implemented |
LL0289 # 03 Y:2008 | 03 | 2008 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $47,583 | $1,290 | Not Implemented |
LL0289 # 04 Y:2008 | 04 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $21,390 | $11,905 | Not Implemented |
LL0289 # 05 Y:2008 | 05 | 2008 | INSULATE BARE EQUIPMENT | $7,830 | $1,940 | Not Implemented |