Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
104
matching recommendationsNAICS | 326291 | Rubber Product Manufacturing for Mechanical Use |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0896 # 03 Y:2014 | 03 | 2014 | MINIMIZE WATER USAGE | $7,067 | $8,000 | Not Implemented |
UD0896 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $683 | $500 | Not Implemented |
UD0896 # 05 Y:2014 | 05 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $22 | $0 | Not Implemented |
UD0896 # 06 Y:2014 | 06 | 2014 | OPTIMIZE PLANT POWER FACTOR | $9,728 | $8,000 | Not Implemented |
UD0896 # 07 Y:2014 | 07 | 2014 | USE OPTIMUM THICKNESS INSULATION | $1,035 | $1,211 | Not Implemented |
UD0896 # 08 Y:2014 | 08 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $794 | $1,000 | Not Implemented |
WV0477 # 01 Y:2013 | 01 | 2013 | INSULATE BARE EQUIPMENT | $3,015 | $2,013 | Implemented |
WV0477 # 02 Y:2013 | 02 | 2013 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,823 | $6,345 | Not Implemented |
WV0477 # 03 Y:2013 | 03 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,064 | $3,573 | Not Implemented |
WV0477 # 04 Y:2013 | 04 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,996 | $1,000 | Not Implemented |
WV0477 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $647 | $1,581 | Not Implemented |
WV0477 # 06 Y:2013 | 06 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $595 | $257 | Implemented |
WV0477 # 07 Y:2013 | 07 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $490 | $1,035 | Implemented |
WV0477 # 08 Y:2013 | 08 | 2013 | INSTALL OCCUPANCY SENSORS | $366 | $135 | Implemented |
WV0477 # 09 Y:2013 | 09 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $260 | $137 | Implemented |
WV0477 # 10 Y:2013 | 10 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $257 | $586 | Not Implemented |
UD0863 # 01 Y:2012 | 01 | 2012 | TREAT AND REUSE RINSE WATERS | $23,578 | $1,000 | Not Implemented |
UD0863 # 02 Y:2012 | 02 | 2012 | COMBINE UTILITY METERS | $4,421 | $8,842 | Not Implemented |
UD0863 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,407 | $16,259 | Implemented |
UD0863 # 04 Y:2012 | 04 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $557 | $0 | Implemented |
UD0863 # 05 Y:2012 | 05 | 2012 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,871 | $8,000 | Not Implemented |
UD0863 # 06 Y:2012 | 06 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $18,285 | $9,900 | Not Implemented |
UD0863 # 07 Y:2012 | 07 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,249 | $0 | Implemented |
UD0863 # 08 Y:2012 | 08 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,548 | $2,000 | Not Implemented |
UD0863 # 09 Y:2012 | 09 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,856 | $1,000 | Implemented |