Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
187
matching recommendationsNAICS | 327 | Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0602 # 03 Y:2020 | 03 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,898 | $2,500 | Implemented |
SD0602 # 02 Y:2020 | 02 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,346 | $568 | Not Implemented |
SD0602 # 01 Y:2020 | 01 | 2020 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $3,957 | $7,500 | Not Implemented |
SD0591 # 07 Y:2020 | 07 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,259 | $75 | Implemented |
SD0591 # 01 Y:2020 | 01 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,538 | $12,557 | Not Implemented |
SD0591 # 02 Y:2020 | 02 | 2020 | USE PHOTOCELL CONTROLS | $4,341 | $4,995 | Not Implemented |
SD0591 # 03 Y:2020 | 03 | 2020 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,858 | $13,600 | Not Implemented |
SD0591 # 04 Y:2020 | 04 | 2020 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,520 | $11,623 | Not Implemented |
SD0591 # 05 Y:2020 | 05 | 2020 | INSTALL OCCUPANCY SENSORS | $2,043 | $900 | Not Implemented |
SD0591 # 06 Y:2020 | 06 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,377 | $45 | Not Implemented |
SF0544 # 05 Y:2019 | 05 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $249,622 | $1,187,556 | Implemented |
SF0544 # 04 Y:2019 | 04 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,820 | $9,188 | Implemented |
SF0544 # 03 Y:2019 | 03 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,026 | $11,278 | Not Implemented |
SF0544 # 02 Y:2019 | 02 | 2019 | MINIMIZE OVERFLOWS BY INSTALLING LEVEL CONTROLS | $1,610 | $2,208 | Implemented |
SF0544 # 01 Y:2019 | 01 | 2019 | TURN OFF EQUIPMENT WHEN NOT IN USE | $920 | $0 | Implemented |
SF0518 # 02 Y:2018 | 02 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,220 | $4,857 | Not Implemented |
SF0518 # 03 Y:2018 | 03 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,611 | $15,000 | Not Implemented |
SF0518 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,777 | $2,300 | Not Implemented |
SF0518 # 05 Y:2018 | 05 | 2018 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $2,098 | $6,325 | Not Implemented |
SF0518 # 06 Y:2018 | 06 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $6,223 | $45,702 | Not Implemented |
SF0518 # 01 Y:2018 | 01 | 2018 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $13,874 | $3,023 | Not Implemented |
SD0519 # 06 Y:2015 | 06 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,572 | $1,500 | Implemented |
SD0519 # 04 Y:2015 | 04 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,983 | $16,500 | Implemented |
SD0519 # 05 Y:2015 | 05 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $3,856 | $210 | Implemented |
SD0519 # 01 Y:2015 | 01 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $15,876 | $6,475 | Implemented |