IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

187

matching recommendations
Reset
NAICS 327 Nonmetallic Mineral Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0365 # 02 Y:2005 02 2005 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $570,334 $1,600,000 Implemented
SD0365 # 03 Y:2005 03 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $313,658 $79,766 Implemented
SD0365 # 04 Y:2005 04 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $75,000 $74,450 Implemented
SD0365 # 05 Y:2005 05 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $65,420 $68,600 Implemented
SD0365 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,645 $13,000 Implemented
SD0365 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,076 $1,300 Implemented
SD0365 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,012 $6,000 Implemented
SD0365 # 09 Y:2005 09 2005 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $11,700 $18,500 Not Implemented
SD0365 # 10 Y:2005 10 2005 INSTALL EQUIPMENT TO MOVE PRODUCT $261,855 $40,000 Implemented
SD0360 # 01 Y:2005 01 2005 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $630,305 $1,330,000 Not Implemented
SD0360 # 02 Y:2005 02 2005 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT $82,741 $534,444 Not Implemented
SD0360 # 03 Y:2005 03 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $61,107 $38,800 Implemented
SD0360 # 04 Y:2005 04 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,456 $3,500 Implemented
SD0360 # 05 Y:2005 05 2005 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $36,000 $20,000 Implemented
SD0360 # 06 Y:2005 06 2005 INSTALL EQUIPMENT TO MOVE PRODUCT $232,996 $340,000 Not Implemented
SF0296 # 01 Y:2004 01 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $850 $282 Implemented
SF0296 # 02 Y:2004 02 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $8,781 $4,375 Implemented
SF0296 # 03 Y:2004 03 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,936 $3,085 Not Implemented
SF0296 # 04 Y:2004 04 2004 USE PHOTOCELL CONTROLS $2,262 $2,760 Not Implemented
SF0296 # 05 Y:2004 05 2004 USE PHOTOCELL CONTROLS $2,058 $2,880 Not Implemented
SF0296 # 06 Y:2004 06 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,715 $2,638 Implemented
SF0296 # 07 Y:2004 07 2004 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $753 $1,520 Implemented
SF0296 # 08 Y:2004 08 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,293 $5,681 Not Implemented
SF0296 # 09 Y:2004 09 2004 USE PHOTOCELL CONTROLS $1,017 $3,059 Implemented
SF0296 # 10 Y:2004 10 2004 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $14,141 $36,000 Not Implemented