Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
167
matching recommendationsNAICS | 327 | Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0869 # 04 Y:2012 | 04 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,400 | $57,000 | Not Implemented |
UD0869 # 05 Y:2012 | 05 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $4,610 | $8,000 | Not Implemented |
UD0869 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,808 | $1,000 | Implemented |
UD0869 # 07 Y:2012 | 07 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,105 | $400 | Not Implemented |
UD0869 # 08 Y:2012 | 08 | 2012 | COVER OPEN TANKS | $1,504 | $1,000 | Not Implemented |
UD0869 # 09 Y:2012 | 09 | 2012 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $64,740 | $51,900 | Not Implemented |
UF0438 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $22,343 | $1,105 | Not Implemented |
UF0438 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $85,202 | $72,075 | Not Implemented |
UF0438 # 03 Y:2010 | 03 | 2010 | AIR CONDITION ONLY SPACE NECESSARY | $15,093 | $1,615 | Not Implemented |
UF0438 # 04 Y:2010 | 04 | 2010 | AIR CONDITION ONLY SPACE NECESSARY | $10,754 | $22,000 | Not Implemented |
UF0438 # 05 Y:2010 | 05 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $112,650 | $154,062 | Not Implemented |
UF0438 # 06 Y:2010 | 06 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $24,615 | $975 | Not Implemented |
UF0438 # 07 Y:2010 | 07 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,023 | $3,670 | Not Implemented |
UF0438 # 08 Y:2010 | 08 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,272 | $2,160 | Not Implemented |
UF0438 # 09 Y:2010 | 09 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $59,220 | $44,118 | Not Implemented |
UF0438 # 10 Y:2010 | 10 | 2010 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $14,054 | $0 | Not Implemented |
UF0438 # 11 Y:2010 | 11 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $14,482 | $0 | Not Implemented |
UF0438 # 12 Y:2010 | 12 | 2010 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $8,717 | $0 | Not Implemented |
UD0825 # 01 Y:2010 | 01 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,398 | $100 | Not Implemented |
UD0825 # 02 Y:2010 | 02 | 2010 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,976 | $2,000 | Not Implemented |
UD0825 # 03 Y:2010 | 03 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,869 | $10,000 | Not Implemented |
UD0825 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,525 | $100 | Not Implemented |
UD0825 # 05 Y:2010 | 05 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,681 | $25 | Not Implemented |
UD0825 # 06 Y:2010 | 06 | 2010 | AVOID REWINDING MOTORS MORE THAN TWICE | $783 | $971 | Not Implemented |
UD0825 # 07 Y:2010 | 07 | 2010 | INSTALL OCCUPANCY SENSORS | $268 | $75 | Not Implemented |