IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

179

matching recommendations
Reset
NAICS 327 Nonmetallic Mineral Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0512 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,467 $549 Implemented
WV0512 # 08 Y:2015 08 2015 INSULATE BARE EQUIPMENT $1,061 $468 Implemented
WV0512 # 09 Y:2015 09 2015 DEVELOP A REPAIR/REPLACE POLICY $762 $554 Implemented
WV0478 # 01 Y:2013 01 2013 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $27,686 $1,000 Implemented
WV0478 # 02 Y:2013 02 2013 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $24,652 $121,800 Not Implemented
WV0478 # 03 Y:2013 03 2013 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $18,929 $1,700 Implemented
WV0478 # 04 Y:2013 04 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $14,341 $2,000 Implemented
WV0478 # 05 Y:2013 05 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $13,408 $7,000 Not Implemented
WV0478 # 06 Y:2013 06 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,430 $6,000 Implemented
WV0478 # 07 Y:2013 07 2013 INSTALL SET-BACK TIMERS $3,604 $740 Implemented
WV0478 # 08 Y:2013 08 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,550 $13,191 Implemented
WV0478 # 09 Y:2013 09 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,006 $5,657 Not Implemented
WV0478 # 10 Y:2013 10 2013 DEVELOP A REPAIR/REPLACE POLICY $1,649 $643 Implemented
WV0478 # 11 Y:2013 11 2013 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,342 $4,080 Not Implemented
WV0418 # 01 Y:2010 01 2010 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $138,747 $25,000 Not Implemented
WV0418 # 02 Y:2010 02 2010 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $81,321 $88,248 Not Implemented
WV0418 # 03 Y:2010 03 2010 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $69,991 $24,464 Not Implemented
WV0418 # 04 Y:2010 04 2010 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $44,522 $17,594 Not Implemented
WV0418 # 05 Y:2010 05 2010 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $35,021 $47,775 Not Implemented
WV0418 # 06 Y:2010 06 2010 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $33,207 $16,040 Not Implemented
WV0418 # 07 Y:2010 07 2010 INSULATE BARE EQUIPMENT $22,652 $9,549 Implemented
WV0418 # 08 Y:2010 08 2010 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $17,763 $2,000 Implemented
WV0418 # 09 Y:2010 09 2010 DEVELOP A REPAIR/REPLACE POLICY $15,821 $1,715 Implemented
WV0418 # 10 Y:2010 10 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,568 $19,614 Implemented
WV0418 # 11 Y:2010 11 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,872 $35,956 Implemented