Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,688
matching recommendationsNAICS | 327 | Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0578 # 02 Y:2005 | 02 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,500 | $780 | Implemented |
OK0717 # 01 Y:2005 | 01 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $38,551 | $53,370 | Implemented |
OK0717 # 02 Y:2005 | 02 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,162 | $7,760 | Not Implemented |
OK0717 # 03 Y:2005 | 03 | 2005 | USE COMPRESSOR AIR FILTERS | $111 | $417 | Not Implemented |
OK0717 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $1,466 | $1,039 | Implemented |
OK0717 # 05 Y:2005 | 05 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $1,002 | $9,712 | Implemented |
OK0717 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,658 | $461 | Not Implemented |
OK0716 # 01 Y:2005 | 01 | 2005 | OPTIMIZE PLANT POWER FACTOR | $10,863 | $38,544 | Not Implemented |
OK0716 # 02 Y:2005 | 02 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,900 | $200 | Not Implemented |
OK0716 # 03 Y:2005 | 03 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $-28,676 | $0 | Not Implemented |
OK0716 # 04 Y:2005 | 04 | 2005 | USE PHOTOCELL CONTROLS | $1,725 | $125 | Not Implemented |
OK0716 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $212 | $475 | Not Implemented |
OK0716 # 06 Y:2005 | 06 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $579 | $25 | Not Implemented |
OK0716 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $153 | $1,346 | Not Implemented |
SF0313 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,370 | $396 | Implemented |
SF0313 # 02 Y:2005 | 02 | 2005 | CHANGE OPERATING CONDITIONS | $1,859 | $0 | Not Implemented |
SF0313 # 03 Y:2005 | 03 | 2005 | USE PHOTOCELL CONTROLS | $3,023 | $714 | Not Implemented |
SF0313 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,078 | $1,561 | Not Implemented |
SF0313 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $959 | $515 | Implemented |
SF0313 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,274 | $27,658 | Implemented |
SF0313 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $7,324 | $9,540 | Not Implemented |
SF0313 # 08 Y:2005 | 08 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,051 | $3,441 | Not Implemented |
SF0313 # 09 Y:2005 | 09 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,672 | $8,006 | Not Implemented |
SF0313 # 10 Y:2005 | 10 | 2005 | USE PHOTOCELL CONTROLS | $3,196 | $7,650 | Not Implemented |
SF0313 # 11 Y:2005 | 11 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,515 | $13,681 | Not Implemented |