Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsNAICS | 327 | Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0483 # 05 Y:2020 | 05 | 2020 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $196 | $226 | Not Implemented |
AS0483 # 04 Y:2020 | 04 | 2020 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $2,057 | $1,070 | Not Implemented |
AS0483 # 03 Y:2020 | 03 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,493 | $4,974 | Not Implemented |
AS0483 # 02 Y:2020 | 02 | 2020 | COMBINE UTILITY METERS | $19,902 | $520 | Not Implemented |
AS0483 # 01 Y:2020 | 01 | 2020 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $26,222 | $200 | Not Implemented |
AS0482 # 04 Y:2020 | 04 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,040 | $1,459 | Implemented |
AS0482 # 03 Y:2020 | 03 | 2020 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,701 | $160 | Implemented |
AS0482 # 02 Y:2020 | 02 | 2020 | COMBINE UTILITY METERS | $5,394 | $416 | Not Implemented |
AS0482 # 01 Y:2020 | 01 | 2020 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,090 | $200 | Implemented |
AS0406 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $28,210 | $1,000 | Not Implemented |
AS0406 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,848 | $1,000 | Not Implemented |
AS0406 # 05 Y:2005 | 05 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $20,625 | $11,478 | Not Implemented |
AS0406 # 04 Y:2005 | 04 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $21,234 | $10,000 | Not Implemented |
AS0406 # 02 Y:2005 | 02 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $46,489 | $10,000 | Not Implemented |
AS0406 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $393,520 | $200,000 | Not Implemented |
AS0363 # 06 Y:2003 | 06 | 2003 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $1,049,273 | $2,100,000 | Not Implemented |
AS0363 # 05 Y:2003 | 05 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $17,401 | $10,050 | Not Implemented |
AS0363 # 04 Y:2003 | 04 | 2003 | INSTALL OCCUPANCY SENSORS | $6,720 | $750 | Implemented |
AS0363 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,751 | $10,939 | Not Implemented |
AS0363 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $265 | $2,353 | Implemented |
AS0363 # 01 Y:2003 | 01 | 2003 | INSTALL SKYLIGHTS | $552 | $22,526 | Not Implemented |
AS0351 # 01 Y:2003 | 01 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $110 | $15 | Not Implemented |
AS0351 # 05 Y:2003 | 05 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $10,220 | $805 | Implemented |
AS0351 # 04 Y:2003 | 04 | 2003 | BURN A LESS EXPENSIVE GRADE OF FUEL | $26,419 | $6,500 | Implemented |
AS0351 # 03 Y:2003 | 03 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $462 | $1,000 | Not Implemented |