Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
406
matching recommendationsNAICS | 32712 | Clay Building Material and Refractories Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0048 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $1,760 | $1,050 | Not Implemented |
DL0048 # 07 Y:2010 | 07 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $20,000 | $41,400 | Not Implemented |
BD0350 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,713 | $8,173 | Implemented |
BD0350 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $4,266 | $2,560 | Implemented |
BD0350 # 03 Y:2008 | 03 | 2008 | USE PHOTOCELL CONTROLS | $1,126 | $450 | Implemented |
BD0350 # 04 Y:2008 | 04 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,395 | $8,740 | Implemented |
BD0350 # 05 Y:2008 | 05 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $81,155 | $81,250 | Not Implemented |
BD0350 # 06 Y:2008 | 06 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,577 | $8,750 | Not Implemented |
BD0350 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,132 | $0 | Not Implemented |
BD0350 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,724 | $625 | Implemented |
BD0350 # 09 Y:2008 | 09 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,592 | $1,080 | Implemented |
BD0350 # 10 Y:2008 | 10 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $52,447 | $9,000 | Implemented |
BD0350 # 11 Y:2008 | 11 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $397,949 | $60,000 | Not Implemented |
BD0350 # 12 Y:2008 | 12 | 2008 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $125,150 | $89,750 | Not Implemented |
BD0350 # 13 Y:2008 | 13 | 2008 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $13,552 | $2,400 | Not Implemented |
BD0350 # 14 Y:2008 | 14 | 2008 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $130,834 | $8,000 | Not Implemented |
UA0022 # 01 Y:2008 | 01 | 2008 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $204,109 | $300,000 | Not Implemented |
UA0022 # 02 Y:2008 | 02 | 2008 | USE OPTIMUM THICKNESS INSULATION | $12,433 | $2,976 | Not Implemented |
UA0022 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,260 | $33,777 | Not Implemented |
UA0022 # 04 Y:2008 | 04 | 2008 | USE PHOTOCELL CONTROLS | $3,768 | $1,894 | Not Implemented |
UA0022 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $994 | $10,283 | Implemented |
UA0022 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $186 | $300 | Implemented |
UA0022 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,127 | $0 | Not Implemented |
UA0022 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,161 | $3,000 | Implemented |
UA0022 # 09 Y:2008 | 09 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,504 | $1,845 | Implemented |