Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
43
matching recommendationsNAICS | 32712 | Clay Building Material and Refractories Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0350 # 14 Y:2008 | 14 | 2008 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $130,834 | $8,000 | Not Implemented |
BD0350 # 13 Y:2008 | 13 | 2008 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $13,552 | $2,400 | Not Implemented |
BD0350 # 12 Y:2008 | 12 | 2008 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $125,150 | $89,750 | Not Implemented |
BD0350 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,713 | $8,173 | Implemented |
BD0350 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $4,266 | $2,560 | Implemented |
BD0350 # 03 Y:2008 | 03 | 2008 | USE PHOTOCELL CONTROLS | $1,126 | $450 | Implemented |
BD0350 # 04 Y:2008 | 04 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,395 | $8,740 | Implemented |
BD0350 # 05 Y:2008 | 05 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $81,155 | $81,250 | Not Implemented |
BD0350 # 06 Y:2008 | 06 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,577 | $8,750 | Not Implemented |
BD0350 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,132 | $0 | Not Implemented |
BD0350 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,724 | $625 | Implemented |
BD0350 # 09 Y:2008 | 09 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,592 | $1,080 | Implemented |
BD0350 # 10 Y:2008 | 10 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $52,447 | $9,000 | Implemented |
BD0350 # 11 Y:2008 | 11 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $397,949 | $60,000 | Not Implemented |
UA0022 # 02 Y:2008 | 02 | 2008 | USE OPTIMUM THICKNESS INSULATION | $12,433 | $2,976 | Not Implemented |
UA0022 # 01 Y:2008 | 01 | 2008 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $204,109 | $300,000 | Not Implemented |
UA0022 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,127 | $0 | Not Implemented |
UA0022 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $186 | $300 | Implemented |
UA0022 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $994 | $10,283 | Implemented |
UA0022 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,161 | $3,000 | Implemented |
UA0022 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,260 | $33,777 | Not Implemented |
UA0022 # 04 Y:2008 | 04 | 2008 | USE PHOTOCELL CONTROLS | $3,768 | $1,894 | Not Implemented |
UA0022 # 09 Y:2008 | 09 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,504 | $1,845 | Implemented |
AM0542 # 05 Y:2008 | 05 | 2008 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,500 | $0 | Implemented |
AM0542 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $12,000 | $18,000 | Not Implemented |