IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

406

matching recommendations
Reset
NAICS 327120 Clay Building Material and Refractories Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0579 # 10 Y:2010 10 2010 USE SYNTHETIC LUBRICANT $1,960 $0 Not Implemented
AM0579 # 11 Y:2010 11 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,320 $900 Not Implemented
BD0377 # 01 Y:2010 01 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $170,550 $385,000 Not Implemented
BD0377 # 02 Y:2010 02 2010 ADJUST BURNERS FOR EFFICIENT OPERATION $30,111 $95,000 Not Implemented
BD0377 # 03 Y:2010 03 2010 USE RADIANT HEATER FOR SPOT HEATING $8,459 $4,240 Implemented
BD0377 # 04 Y:2010 04 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,884 $8,376 Not Implemented
BD0377 # 05 Y:2010 05 2010 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,157 $4,910 Not Implemented
BD0377 # 06 Y:2010 06 2010 INSTALL OCCUPANCY SENSORS $675 $825 Implemented
BD0377 # 07 Y:2010 07 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $600 $1,670 n/a
BD0377 # 08 Y:2010 08 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $596 $10 n/a
BD0377 # 09 Y:2010 09 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $326 $350 Not Implemented
BD0377 # 10 Y:2010 10 2010 USE PHOTOCELL CONTROLS $240 $300 Not Implemented
WV0404 # 01 Y:2010 01 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $795,452 $529,924 Not Implemented
WV0404 # 02 Y:2010 02 2010 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $464,158 $180,000 Not Implemented
WV0404 # 03 Y:2010 03 2010 RECOVER WASTE HEAT FROM EQUIPMENT $151,596 $109,360 Not Implemented
WV0404 # 04 Y:2010 04 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $45,647 $65,720 Implemented
WV0404 # 05 Y:2010 05 2010 USE RADIANT HEATER FOR SPOT HEATING $31,815 $12,720 Implemented
WV0404 # 06 Y:2010 06 2010 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $27,235 $6,000 Implemented
WV0404 # 07 Y:2010 07 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,958 $3,400 Implemented
WV0404 # 08 Y:2010 08 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,603 $1,272 Not Implemented
DL0048 # 01 Y:2010 01 2010 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $25,056 $100 Not Implemented
DL0048 # 02 Y:2010 02 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,459 $100 Implemented
DL0048 # 03 Y:2010 03 2010 INSTALL TIMERS AND/OR THERMOSTATS $6,420 $112 Implemented
DL0048 # 04 Y:2010 04 2010 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $2,452 $1,310 Not Implemented
DL0048 # 05 Y:2010 05 2010 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $13,596 $0 Implemented