Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
57
matching recommendationsNAICS | 3272 | Glass and Glass Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0136 # 06 Y:2006 | 06 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,680 | $100 | Implemented |
MI0136 # 05 Y:2006 | 05 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,760 | $0 | Implemented |
MI0136 # 04 Y:2006 | 04 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,010 | $2,506 | Not Implemented |
MI0136 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,741 | $1,074 | Implemented |
MI0136 # 02 Y:2006 | 02 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,544 | $146 | Not Implemented |
MI0136 # 01 Y:2006 | 01 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $36,851 | $40,224 | Implemented |
UF0365 # 02 Y:2005 | 02 | 2005 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $3,910 | $1,245 | Not Implemented |
UF0365 # 03 Y:2005 | 03 | 2005 | INSTALL SKYLIGHTS | $3,628 | $9,645 | Not Implemented |
UF0365 # 01 Y:2005 | 01 | 2005 | USE PHOTOCELL CONTROLS | $4,861 | $2,070 | Not Implemented |
UF0365 # 08 Y:2005 | 08 | 2005 | IMPROVE SPACE COMFORT CONDITIONING | $2,528 | $8,978 | Implemented |
UF0365 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,236 | $6,602 | Not Implemented |
UF0365 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,277 | $0 | Implemented |
UF0365 # 05 Y:2005 | 05 | 2005 | ADD AREA LIGHTING SWITCHES | $1,633 | $6,615 | Not Implemented |
UF0365 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,178 | $565 | Implemented |
MI0112 # 05 Y:2005 | 05 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,504 | $1,393 | Implemented |
MI0112 # 04 Y:2005 | 04 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,289 | $600 | Implemented |
MI0112 # 03 Y:2005 | 03 | 2005 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $19,066 | $8,226 | Implemented |
MI0112 # 02 Y:2005 | 02 | 2005 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $89,581 | $90 | Implemented |
MI0112 # 01 Y:2005 | 01 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $319,237 | $91,320 | Not Implemented |
MI0102 # 01 Y:2005 | 01 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $100,313 | $40,224 | Not Implemented |
MI0102 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,049 | $870 | Not Implemented |
MI0102 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,890 | $162 | Not Implemented |
MI0102 # 03 Y:2005 | 03 | 2005 | REDUCE DEFECTS BY REDUCING PRODUCT TIPPING | $23,325 | $1,104 | Not Implemented |
MI0102 # 02 Y:2005 | 02 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $66,212 | $29,320 | Not Implemented |
MI0088 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $-1,117 | $750 | Implemented |