Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
93
matching recommendationsNAICS | 3272 | Glass and Glass Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0753 # 05 Y:2015 | 05 | 2015 | INSULATE BARE EQUIPMENT | $1,226 | $1,400 | Implemented |
MA0753 # 02 Y:2015 | 02 | 2015 | REDUCE VENTILATION AIR | $7,290 | $5,575 | Implemented |
MA0753 # 03 Y:2015 | 03 | 2015 | REDUCE VENTILATION AIR | $4,632 | $6,000 | Implemented |
MA0753 # 01 Y:2015 | 01 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $18,534 | $67,200 | Not Implemented |
MA0753 # 04 Y:2015 | 04 | 2015 | INSTALL OCCUPANCY SENSORS | $1,608 | $4,608 | Implemented |
MA0753 # 06 Y:2015 | 06 | 2015 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $842 | $2,152 | Not Implemented |
DL0155 # 02 Y:2015 | 02 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $500 | $0 | Implemented |
DL0155 # 01 Y:2015 | 01 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,690 | $0 | Implemented |
DL0155 # 03 Y:2015 | 03 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $8,960 | $6,880 | Not Implemented |
DL0155 # 04 Y:2015 | 04 | 2015 | SHADE WINDOWS FROM SUMMER SUN | $1,760 | $6,840 | Not Implemented |
DL0155 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,405 | $13,615 | Not Implemented |
NC0556 # 05 Y:2015 | 05 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $1,836 | $4,256 | Implemented |
NC0556 # 01 Y:2015 | 01 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $59,808 | $90,000 | Implemented |
NC0556 # 02 Y:2015 | 02 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,806 | $5,000 | Not Implemented |
NC0556 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,438 | $12,000 | Implemented |
NC0556 # 04 Y:2015 | 04 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,076 | $3,200 | Not Implemented |
NC0556 # 08 Y:2015 | 08 | 2015 | INSTALL OCCUPANCY SENSORS | $578 | $868 | Implemented |
NC0556 # 06 Y:2015 | 06 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,228 | $200 | Not Implemented |
NC0556 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,584 | $8,350 | Implemented |
UK1512 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,263 | $178 | Not Implemented |
UK1512 # 12 Y:2015 | 12 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $277 | $475 | Not Implemented |
UK1512 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,250 | $4,650 | Not Implemented |
UK1512 # 01 Y:2015 | 01 | 2015 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,559 | $0 | Implemented |
UK1512 # 06 Y:2015 | 06 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,652 | $1,750 | Implemented |
UK1512 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,043 | $1,215 | Not Implemented |