Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
459
matching recommendationsNAICS | 3279 | Other Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0478 # 11 Y:2013 | 11 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,342 | $4,080 | Not Implemented |
OK0864 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $33,277 | $58,900 | Not Implemented |
OK0864 # 02 Y:2013 | 02 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $655 | $1,128 | Not Implemented |
OK0864 # 03 Y:2013 | 03 | 2013 | INSULATE BARE EQUIPMENT | $2,872 | $1,478 | Not Implemented |
OK0864 # 04 Y:2013 | 04 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $5,084 | $0 | Implemented |
OK0864 # 05 Y:2013 | 05 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $8,999 | $27,500 | Not Implemented |
OK0864 # 06 Y:2013 | 06 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,158 | $10,250 | Implemented |
OK0864 # 07 Y:2013 | 07 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $46,176 | $10,642 | Implemented |
OK0864 # 08 Y:2013 | 08 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $127,574 | $25,000 | Not Implemented |
OK0864 # 09 Y:2013 | 09 | 2013 | USE FLUE GAS RECUPERATION TO REDUCE VOC | $79,353 | $32,100 | Implemented |
MA0714 # 01 Y:2013 | 01 | 2013 | BURN A LESS EXPENSIVE GRADE OF FUEL | $64,988 | $67,000 | Implemented |
MA0714 # 02 Y:2013 | 02 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,831 | $5,568 | Implemented |
MA0714 # 03 Y:2013 | 03 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,362 | $13,800 | Implemented |
MA0714 # 04 Y:2013 | 04 | 2013 | INSULATE BARE EQUIPMENT | $4,919 | $12,300 | Not Implemented |
MA0714 # 05 Y:2013 | 05 | 2013 | INSULATE BARE EQUIPMENT | $4,187 | $7,500 | Not Implemented |
MA0714 # 06 Y:2013 | 06 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,354 | $9,300 | Not Implemented |
MA0714 # 07 Y:2013 | 07 | 2013 | OPTIMIZE PLANT POWER FACTOR | $11,188 | $13,500 | Implemented |
MA0714 # 08 Y:2013 | 08 | 2013 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $1,360 | $150 | Implemented |
WM0027 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,697 | $644 | Implemented |
WM0027 # 02 Y:2013 | 02 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,649 | $276 | Implemented |
WM0027 # 03 Y:2013 | 03 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $8,153 | $5,600 | Implemented |
WM0027 # 04 Y:2013 | 04 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,126 | $1,240 | Not Implemented |
WM0027 # 05 Y:2013 | 05 | 2013 | ADD AREA LIGHTING SWITCHES | $191 | $400 | Not Implemented |
WM0027 # 06 Y:2013 | 06 | 2013 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $344 | $1,545 | Not Implemented |
WM0027 # 07 Y:2013 | 07 | 2013 | MODIFY WORKLOAD | $53,406 | $0 | Not Implemented |